PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
k
k
CAUTION
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
On the standard screen, if you press function switch “F4”,
“Aftertreatment Devices Regeneration” screen is dis-
played.
(If the screen is not displayed, operate function switches
“F6” and “F7” to display “Aftertreatment Devices Regener-
ation” screen.)
2.
On “Aftertreatment Devices Regeneration” screen, select
“Cancel of Regeneration Disable”, and then press function
switch “F4”.
“Cancel of Regeneration Disable” confirmation screen is
displayed.
3.
On “Regeneration Disable” confirmation screen, press
function switch “F4”.
The screen returns to “Aftertreatment Devices Regenera-
tion” screen, and the regeneration disable is canceled.
REMARK
If you press function switch “F3”, regeneration disable is
not canceled and screen returns to “Aftertreatment Devi-
ces Regeneration” screen.
EXPLANATION OF COMPONENTS
OPERATION
3-128
Содержание PC45MR-30403
Страница 61: ......
Страница 62: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 64: ...14 Engine rear cover 15 Cooling cover 16 Battery 17 KDPF OPERATION GENERAL VIEW 3 3...
Страница 310: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 411: ......
Страница 412: ...SPECIFICATIONS 5 1...
Страница 417: ......
Страница 459: ......
Страница 460: ...REPLACEMENT PARTS 7 1...
Страница 475: ...PC45MR 5 PC55MR 5 HYDRAULIC EXCAVATOR Form No TEN00763 04 2018 KOMATSU All Rights Reserved Printed in Japan 02 2018...