MAINTENANCE
MAINTENANCE SCHEDULE TABLE
4–31
CHECK AND MAINTENANCE AIR CONDITIONER
CHECK AND MAINTENANCE AIR CONDITIONER:ALL-K500-001K01A
CHECK LEVEL OF REFRIGERANT (GAS)
CHECK LEVEL OF REFRIGERANT (GAS):PC220-K512-21DK00A
k
WARNING
If the refrigerant used in the air conditioner gets into your eyes or on your hands, it may cause loss of
sight or frostbite. Do not touch the refrigerant. Never loosen any part of the refrigerant circuit.
Do not bring any flame close to any point where the refrigerant gas is leaking.
If there is a lack of refrigerant (Freon 134a), the cooling perfor-
mance will be poor. When the engine is running at full throttle
and the cooler is running at high speed, look at the sight glass
(1) (inspection window) in the refrigerant hose fitting to check
the condition of the refrigerant gas (Freon 134a) flowing in the
refrigerant circuit.?
(A) No bubbles in refrigerant flow: Suitable
(B) Some bubbles in flow (bubbles pass continuously):
Lack of refrigerant
(C) Colourless, transparent: No refrigerant
REMARK
When there are bubbles, the refrigerant gas level is low, so
contact your Komatsu distributor to have refrigerant added. If
the air conditioner is run with the refrigerant gas level low, it will
cause damage to the compressor.
INSPECTION DURING OFF SEASON
Inspection During Off Season:ALL-K500-20DK00A
Even during the off-season, operate the air conditioner for three to five minutes once a month to maintain the oil
film at all parts of the compressor.
INSPECTION AND MAINTENANCE ITEMS
Inspection and Maintenance Items:ALL-K500-208K00A
Check, maintenance items
Content of check, maintenance
Guideline for maintenance
interval
Refrigerant (gas)
Charge amount
Twice a year (spring, autumn)
Air conditioner condenser
Clogged fins
Every 500 hours
Compressor
Operating condition
Every 4000 hours
V-belt
Damage, tension
Every 250 hours
Blower motor, fan
Operating condition(does it make abnormal
noise?)
When required
Control mechanism
Operating condition (does it function normally?) When required
Piping mounts
Mounting condition, looseness at tightening or
connecting portions, leakage of gas, damage
When required
Содержание PC210-10 DEMOLITION BASE SPEC.
Страница 2: ......
Страница 14: ...PRODUCT INFORMATION FOREWORD 1 12...
Страница 75: ...OPERATION GENERAL VIEW 3 5...
Страница 159: ...OPERATION EXPLANATION OF COMPONENTS 3 89...
Страница 251: ...OPERATION MACHINE OPERATIONS AND CONTROLS 3 181...
Страница 332: ...MAINTENANCE SCHEDULE TABLE MAINTENANCE 4 22 26 Close engine hood 1...
Страница 392: ...END OF SERVICE LIFE MAINTENANCE 4 82...
Страница 393: ...SPECIFICATIONS 5 1 SPECIFICATIONS SPECIFICATIONS ALL 0000 001K04A SPECIFICATIONS...
Страница 397: ...SPECIFICATIONS SPECIFICATIONS 5 5 PC210 10...
Страница 398: ...SPECIFICATIONS SPECIFICATIONS 5 6 PC210LC 10...
Страница 444: ...RECOMMENDED ATTACHMENT OPERATIONS ATTACHMENTS AND OPTIONS 6 46...
Страница 445: ...REPLACEMENT PARTS 7 1 REPLACEMENT PARTS Replacement parts ALL 0000 001K16A REPLACEMENT PARTS...
Страница 453: ...8 1 INDEX...
Страница 457: ...COLOPHON 18...