Switching method of breaker and general attachment
Install an optional attachment and set the working mode to B mode.
Hydraulic oil flowing through breaker circuit passes through additional filter for breaker. Relief valve is set to low
pressure. Maximum oil flow can be adjusted in user mode.
Set pressure of safety valve of service valve (when shipped from plant): 24.5 MPa {250 kg/cm
2
}
Breaker circuit (one-way circuit) is formed.
Crusher or other attachment with 2-way circuit
Install an optional attachment and set the working mode to ATT/P or ATT/E mode.
Hydraulic oil flowing through crusher circuit does not pass through additional filter for breaker. Relief valve is set
to high pressure. Maximum oil flow can be adjusted in user mode.
Set pressure of safety valve of service valve (when shipped from plant): 29.9 MPa {305 kg/cm
2
}
Crusher circuit (2-way circuit) is formed.
METHOD FOR REMOVING AND INSTALLING ATTACHMENT
k
k
WARNING
Lower the attachment to the ground and stop the engine.
METHOD FOR REMOVING ATTACHMENT
1.
Turn the starting switch to ON (B) position.
2.
Set the lock lever to FREE position (F).
HANDLE MACHINE READY FOR INSTALLATION OF ATTACHMENT
ATTACHMENTS AND OPTIONS
6-16
Содержание HB365LC-3
Страница 2: ......
Страница 25: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 5...
Страница 73: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 348: ......
Страница 349: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 436: ......
Страница 437: ...SPECIFICATIONS 5 1...
Страница 441: ...HB365LC 3 SPECIFICATIONS SPECIFICATIONS 5 5...
Страница 442: ...HB365NLC 3 SPECIFICATIONS SPECIFICATIONS 5 6...
Страница 489: ...REPLACEMENT PARTS 7 1...
Страница 505: ......
Страница 506: ...HB365LC 3 HYDRAULIC EXCAVATOR Form No UENAM01292 2017 KOMATSU All Rights Reserved Printed in Belgium 02 2017...