METHOD FOR CANCELING AUTOMATIC WARM-UP OPERATION
If it becomes necessary in an emergency to cancel the auto-
matic warm-up operation or to lower the engine speed to low
idle, do as follows.
1.
Turn fuel control dial (2) to High idle (MAX) position and
hold it for 3 seconds or more.
2.
Turn fuel control dial (2) to Low idle (MIN) position.
The engine automatic warm-up is canceled, and the en-
gine speed is lowered.
REMARK
Turbo protect function takes priority over the engine automatic warm-up.
When the turbo protect function activates, run the engine at low idle even the engine coolant temperature is
30 °C or less. Then the engine automatic warm-up starts automatically to increase the engine speed.
OPERATION
MACHINE OPERATIONS AND CONTROLS
3-173
Содержание HB215LC-3
Страница 2: ......
Страница 11: ...Do not jump down from the cab or machine Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 9...
Страница 24: ......
Страница 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3...
Страница 72: ......
Страница 73: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 344: ......
Страница 345: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 359: ...Fuel main fil ter cartridge Replace Replace Replace Replace MAINTENANCE MAINTENANCE SCHEDULE 4 15...
Страница 431: ...SPECIFICATIONS 5 1...
Страница 474: ......
Страница 475: ...REPLACEMENT PARTS 7 1...
Страница 482: ......
Страница 491: ......
Страница 492: ...HB215LC 3 HYDRAULIC EXCAVATOR Form No UENAM01522 2019 KOMATSU All Rights Reserved Printed in Belgium 02 2019...