
OPERATION
EXPLANATION OF COMPONENTS
3-31
BUZZER CANCEL SWITCH
This switch (2) is used to operate control panel B (multi-information) or to stop the alarm buzzer.
When the switch is released, it returns automatically to the cen-
ter position.
q
When display panel B (multi-information) is in the
operation mode
q
When the alarm buzzer is sounding, turn this switch to
the
position to stop the buzzer.
q
If the switch is held at the position for at least 2.5
seconds, the display switches to the maintenance
mode.
q
When display panel B (multi-information) is in the maintenance mode
position: Cancel or reset to operation mode
position: Confirms selection or selected item
For details, see “METHOD OF USING MAINTENANCE MODE (3-21)“.
INFORMATION SWITCH
This switch (3) is used to operate display panel B (multi-information).
When the switch is released, it returns automatically to the cen-
ter position.
q
When display panel B (multi-information) is in the
operation mode
turn the switch to < or > to switch the display to service
meter or engine speed.
q
When display panel B (multi-information) is in the
maintenance mode
It is used to move between sub modes, between items, to
move the cursor, or to change values.
For details, see “METHOD OF USING MAINTENANCE
MODE (3-21)“.
REVERSE TRAVEL SPEED SETTING SWITCH
This switch (4) can be used to set the reverse travel speed to a
different setting from the forward travel speed.
For details, see “REVERSE TRAVEL SPEED INDICATOR (3-
13)“.
Содержание D31EX-21
Страница 2: ......
Страница 3: ...FOREWORD 11...
Страница 52: ...PRECAUTIONS FOR MAINTENANCE SAFETY 2 34...
Страница 181: ...MAINTENANCE 14 WARNING Please read and make sure that you understand the safety volume before reading this section...
Страница 237: ...SPECIFICATIONS 15...
Страница 240: ...SPECIFICATIONS SPECIFICATIONS 5 4...
Страница 251: ...INDEX 17...
Страница 252: ...INDEX 7 2...
Страница 255: ...COLOPHON 18...