![Komatsu D155AX-8E0 Скачать руководство пользователя страница 307](http://html1.mh-extra.com/html/komatsu/d155ax-8e0/d155ax-8e0_operation-and-maintenance-manual_1991326307.webp)
METHOD FOR STARTING ENGINE
1.
Check both of normal machine and failed machine that the lock lever is set to LOCK position.
2.
Check both of normal machine and failed machine that the control levers are in NEUTRAL position.
3.
Make sure the clips are firmly connected to the battery terminals.
4.
Start the engine of the normal machine and run it at high idle (Max. speed).
5.
Turn the starting switch of the failed machine to START position and start the engine.
If the engine does not start at first, try again after 2 minutes or more.
PROCEDURE FOR REMOVING JUMPER CABLE
After the engine has started, disconnect the jumper cables in the reverse of the order in which they were con-
nected.
1.
Remove the clip of jumper cable (B) from engine cylinder
block (E) on the failed machine.
2.
Remove the clip of jumper cable (B) from the negative (-)
terminal of battery (D) on the normal machine.
3.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (D) on the normal machine.
4.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (C) on the failed machine.
OTHER TROUBLE
PHENOMENA AND ACTIONS FOR ELECTRICAL SYSTEM
• For the remedies indicated with (*) in the remedy column, always contact your Komatsu distributor.
• In cases of problems or causes which are not listed below, ask your Komatsu distributor for repairs.
Problem
Main causes
Remedy
Lamp does not glow brightly even
when the engine runs at high speeds.
Defective wiring, deterioration of bat-
tery
Check and repair loose terminal or
wire breakage, replace battery. (*)
Defective belt tension
Replace alternator belt. For details,
see Every500 hours maintenance.
Lamp flickers while engine is running. Defective wiring, deterioration of bat-
tery
Check and repair loose terminal or
wire breakage, replace battery. (*)
Defective belt tension
Replace alternator belt. For details,
see Every500 hours maintenance.
Charge level caution lamp does not
go out even when engine is running.
Defective alternator
Replace. (*)
Defective wiring
Check, repair. (*)
Alternator produces unusual noise.
Defective alternator
Replace. (*)
Starting motor does not rotate even
when starting switch is turned to
START position.
Defective wiring
Check, repair. (*)
Insufficient battery charge
Charge battery.
Battery disconnect switch is at OFF
position.
Turn ON.
Engine shutdown secondary switch at
“STOP ENGINE” position
Set it to “NORMAL” position.
Defective adjustment of safety switch Adjust safety switch. (*)
Pinion of starting motor repeats en-
gaging and disengaging (rattles).
Insufficient battery charge
Charge battery.
OPERATION
TROUBLES AND ACTIONS
3-245
Содержание D155AX-8E0
Страница 2: ......
Страница 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Страница 13: ...Evaluation height 1 2m above the ground Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Страница 24: ......
Страница 63: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 312: ......
Страница 313: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 397: ...SPECIFICATIONS 5 1...
Страница 403: ...HANDLE HEADREST Keep the headrest inserted to the end ATTACHMENTS AND OPTIONS HANDLE HEADREST 6 5...
Страница 404: ......
Страница 405: ...REPLACEMENT PARTS 7 1...
Страница 420: ...D155AX 8E0 BULLDOZER Form No EENAM03780 2019 KOMATSU All Rights Reserved Printed in Belgium 04 2019...