15. Tap the ENTER button and the display returns to the work-
ing screen.
16. On the standard working screen, check that Blade Edge
Position button is surrounded by yellow frame.
METHOD FOR CALIBRATING BUCKET TOOTH
When bucket tooth has been worn and shortened, the tooth length setting can be adjusted with Bucket Configu-
ration in Machine Setup menu.
1.
Tap the menu button on the control box.
Menu screen is displayed.
2.
Tap the “Machine Setup” button.
The display changes to the Machine Setup screen.
AJD01421
EXECUTIONS
DAILY CALIBRATION