6.3.2 Warning messages
Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO contact remains
closed), are indicated in the LED display on the front panel by a coded warning number.
Some warning messages result in a controlled shut-down of the drive (braking by emergency stop ramp). The
servo amplifier reaction depends on the warning (see
).
Number Designation
Explanation
E/P
Status Messages
Status messages, no error
. . .
Status Message
Updating the startup configuration
-
Status Message
Programming mode
- S -
STO-Enable
STO-Enable input is 0V (with disabled drive only)
n01
I²t
I²t threshold exceeded
n02
Brake power
Reached preset electrical brake power limit
n03
S_fault
Exceeded preset following error limit
n04
Response monitoring
Response monitoring (fieldbus) has been activated
n05
Supply phase
Mains supply phase missing
n06
SW limit switch 1
Underrun software limit switch 1
n07
SW limit switch 2
Overrun software limit switch 2
n08
Motion task error
A faulty motion task was started
n09
No reference point
No reference point (Home) set at start of motion task
n10
PSTOP
PSTOP limit-switch activated
n11
NSTOP
NSTOP limit-switch activated
n12
Motor default values
loaded
Only for ENDAT/ HIPERFACE: discrepancy between motor number
saved in the encoder and the amplifier, motor default values loaded
n13
Slot warning
24V supply of the I/O expansion board is missing
n14
SinCos feedback
SinCos commutation (wake & shake) not completed, will be can-
celed when amplifier is enabled and wake & shake carried out
n15
Reserve
Reserve
n16
Summarized warning
Summarized warning for n17 to n31
n17
Fielbus Synchronization
CAN sync is not logged in
n18
Multiturn overrun
Max. number of motor turns exceeded
n19
Motion task ramps are limited Range overflow on motion task data
n20
Invalid motion task
Invalid motion task
n21
PLC program error
For details see plc code
n22
max. motor temperatur
reached
The user can shut down the process before the temperature eror will
interrupt the process immediately
n23
Sin Cos feedback
Warning level reached
n24
Digital I/O
Configuration is not logical
n25...n31 reserved
reserved
n32
firmware beta version
Firmware is an unreleased beta version
More information to the messages can be found in the ASCII Object Reference (
), see parameter
. Hints for removal can be found in section
" of the online help.
S300 Safety Guide | 6 Appendix
Kollmorgen | wiki-kollmorgen.eu | December 2015
149
Содержание SERVOSTAR 300
Страница 30: ...S300 Safety Guide 1 Deutsch 30 Kollmorgen wiki kollmorgen eu December 2015...
Страница 58: ...S300 Safety Guide 2 English 58 Kollmorgen wiki kollmorgen eu December 2015...
Страница 86: ...S300 Safety Guide 3 Fran ais 86 Kollmorgen wiki kollmorgen eu December 2015...
Страница 114: ...S300 Safety Guide 4 Italiano 114 Kollmorgen wiki kollmorgen eu December 2015...
Страница 117: ...5 1 2 PDF 5 1 3 Symbol S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 117...
Страница 122: ...S300 Safety Guide 5 5 2 3 UN 230 B S300 122 Kollmorgen wiki kollmorgen eu December 2015...
Страница 126: ...S300 Safety Guide 5 5 3 2 SERVOSTAR 300 126 Kollmorgen wiki kollmorgen eu December 2015...
Страница 136: ...S300 Safety Guide 5 5 6 5 6 1 Wichtige Hinweise 900 5 60 AENA 1 30 L1 L2 136 Kollmorgen wiki kollmorgen eu December 2015...
Страница 137: ...5 6 2 Return 5 6 2 1 5 6 2 2 S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 137...
Страница 139: ...5 6 3 3 S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 139...
Страница 147: ...6 2 2 Connection overview SERVOSTAR 300 S300 Safety Guide 6 Appendix Kollmorgen wiki kollmorgen eu December 2015 147...
Страница 153: ...S300 Safety Guide Kollmorgen wiki kollmorgen eu December 2015 153...