IDN405 Probe 1 Enable
Used to arm the position capture mechanism so that the next valid probing signal edge
captures the current position into IDN130 or 131. IDN405 may be assigned to a RTC bit
(MDT control word bit 6 or 7) through IDN301 or IDN303. This IDN is write-protected
while it is assigned to a RTC bit and could only reset to 0 via the System Communica-
tions. Refer to IDN170 and IDNP3038 for more information.
Data Length: 2 bytes
Non-Volatile:
No
Data Type:
Binary
Write Access:
CP2, CP3, CP4
Minimum:
0
Run-Up Check:
Maximum:
1
Cyclic Transfer:
Default:
ASCII Param.:
3.176
IDN406 Probe 2 Enable
Used to arm the position capture mechanism so that the next valid probing signal edge
captures the current position into IDN132 or 133. IDN406 may be assigned to a RTC bit
(MDT control word bit 6 or 7) through IDN301 or IDN303. This IDN is write-protected
while it is assigned to a RTC bit and could only reset to 0 via the System Communica-
tions. Refer to IDN170 and IDNP3038 for more information.
Data Length: 2 bytes
Non-Volatile:
No
Data Type:
Binary
Write Access:
CP2, CP3, CP4
Minimum:
0
Run-Up Check:
Maximum:
1
Cyclic Transfer:
Default:
ASCII Param.:
3.177
IDN409 Probe 1 Positive Edge Latched Status
Indicates whether captured position data has been latched within IDN130 after the rising
edge of the probe 1 input signal (IDN401). Position data can only be latched on the posi-
tive edge of probe 1 if the “Probing” procedure (IDN170) is active and the “Probe Control
Parameter” (IDN169) has been configured to use the positive edge of probe 1.
Additionally, probe 1 must be armed by setting the “Probe 1 Enable” (IDN405). After arm-
ing probe 1, the next probe 1 rising edge will capture the current position and the “probe 1
positive edge latched status” will set when the captured data is available in IDN130. Once
the latched status has been set, no more position captures will occur on the rising edges
of the probe 1 input until the master re-arms probe 1 by clearing and setting the probe 1
enable. Clearing the probe 1 enable signal will reset the latch status.
IDN409 duplicates information found in the probe status (IDN179, bit 0). IDN409 may be
assigned to a RTS bit (AT status word bit 6 or 7) through IDN305 or IDN307.
Data Length: 2 bytes
Non-Volatile:
No
Data Type:
Binary
Write Access:
Read-only
Minimum:
Run-Up Check:
Maximum:
Cyclic Transfer:
Default:
0
ASCII Param.:
82
sercos
®
for S300/S700
sercos
®
IDN Set
04/2016
Kollmorgen