background image

 

Ethernet-Gateway

 

 

Configuration 

1.3  Set the Network  

 

Do_vl_moxa2 / 50% 

 

dialog fields: 

<<Server Name>>

 

 

 

key in the name for identifying the gateways. Please remember that this input is optional and 
is not a network name  

<<IP Address>>*

 

 

 

key in the IP address here where the gateway can be reached 

<<network mask>>*

 

 

 

key in the network mask here for determining the targeted network  

<<gateway>>*

 

 

 

key in the IP address of the gateway here for a connection to another network  

<<IP Configuration>>

 

 

 

retain the <<Static IP>> setting 

* you can get this information from the network administrator 

 

23.09.2010

 

5

 

Содержание N-Port Express DE-311

Страница 1: ...fice Village D 51109 Köln Chester Business Park Telefon 49 0 221 89 85 0 Chester Cheshire CH4 9QP Telefax 49 0 221 89 85 30 Telephone 44 0 1244 67 85 49 http www kollmorgen de Fax 44 0 1244 68 15 78 Email info kollmorgen de Email info kollmorgen co uk KOLLMORGEN Steuerungstechnik GmbH Köln 23 09 2010 DO_EthernetGW_konfig_gb ...

Страница 2: ...t the Network 5 3 2 Set the Operating State 6 3 3 Set the Serial Interface 7 4 Ethernet Gateway NPort 5110 8 5 Introduction 8 6 Configuring the Ethernet Gateway 8 6 1 Set the Network 10 6 2 Set the Serial Interface 11 6 3 Set the Operating State 12 6 4 Template import configuration 14 6 5 Model for the Configuration Data Sheet 16 2 23 09 2010 ...

Страница 3: ...S OVER cable Gateway Laptop CROSS OVER cable RS232 Ethernet connection interfacing via the standard in house network Laptop Ethernet Network Gateway RS232 The descriptions below refer to the direct Ethernet connection that we recommend and they require the standard factory setting for the configuration If you would like to reconfigure a machine already that has already configured reset all values ...

Страница 4: ...r Start Program Nport Management Suite 2 start a network scan under Locate Server Broadcast Search 3 the gateway appears in the display 4 select the gateway input and press the right hand mouse button for the context menu 5 select the Modify Configuration input Do_vl_moxa1 50 4 23 09 2010 ...

Страница 5: ... and is not a network name IP Address key in the IP address here where the gateway can be reached network mask key in the network mask here for determining the targeted network gateway key in the IP address of the gateway here for a connection to another network IP Configuration retain the Static IP setting you can get this information from the network administrator 23 09 2010 5 ...

Страница 6: ...tate Do_vl_moxa3 50 dialog fields Change OP_Mode tick here and select the TCP Server input from the Port 1 list More settings press the button and key in the port number 8000 in the TCP Port space TCP alive check time set the value to 1 minute 6 23 09 2010 ...

Страница 7: ...iguration 1 5 Set the Serial Interface Do_vl_moxa4 dialog fields Change Serial Port Settings tick here select the transmission rate 9600 from the Baud Rate list select the None input from the Flow Control list 23 09 2010 7 ...

Страница 8: ...2 2 Configuring the Ethernet Gateway You can choose two ways to configure it direct Ethernet connection between the gateway and PC via CROSS OVER cable Gateway Laptop CROSS OVER Kabel RS232 Ethernet Verbindung interfacing via the standard in house network Laptop Ethernet Netzwerk Gateway RS232 The descriptions below refer to the direct Ethernet connection that we recommend and they require the sta...

Страница 9: ...put under Nport Administrator 2 Start a network scan under Configuration Broadcast Search 3 The gateway appears in the display ED_DO_MOXA 5110 B02 Bild 55 4 Select the gateway input and press the right hand mouse button for the context menu 5 Select the Configure input ED_DO_MOXA 5110 B03 Bild 55 23 09 2010 9 ...

Страница 10: ...tion 2 3 Set the Network ED_DO_MOXA 5110 B04 Bild50 Dialog fields Modify tick here IP Address key in the IP address here where the gateway can be reached you can get this information from the network administrator 10 23 09 2010 ...

Страница 11: ...MOXA 5110 B05 png Bild 50 dialog fields Modify Tick here Select the gateway input Press the button Settings for detailed settings ED_DO_MOXA 5110 B06 png Bild 50 dialog fields Baud Rate Select the transmission rate 9600 Flow Control Select the None input 23 09 2010 11 ...

Страница 12: ...ernet Gateway Configuration 2 5 Set the Operating State ED_DO_MOXA 5110 B07 png Bild 50 dialog fields Modify Tick here Select the gateway input Press the button Settings for detailed settings 12 23 09 2010 ...

Страница 13: ... Configuration ED_DO_MOXA 5110 B08 png Bild 50 dialog fields Operating Mode Choose TCP Server Mode out of the list Local TCP Port Feed in portnumber 8000 TCP Alive Check Timeout Set the value to 1 minute 23 09 2010 13 ...

Страница 14: ...g Bild 55 1 Start a network scan under Configuration Broadcast Search 2 The gateway appears in the display 3 Select the gateway input and press the right hand mouse button for the context menu 4 Select the Import Configuration input 5 Immediately you reach the basic settings 14 23 09 2010 ...

Страница 15: ...for Gateway identification Please remember that this input is optional and is not a network name Please note the standard IP address is pledged in the imported data file Change the preset IP address if necessary please look up 4 1 network settings Modify Tick here Enable Web Console Tick here Enable Telnet Console Tick here 23 09 2010 15 ...

Страница 16: ...isualLift version MPK lift version MPK installation ID DLON IO interface version DLON v 24 gateway version gateway model name gateway Ethernet MAC address gateway server name gateway IP address network mask network gateway address IP configuration static IP gateway mode TCP server TCP server port 8000 serial parameters if available needed ...