I/O Terminal /
OVERVIEW
8
2.1.1 Technical Data
This section provides the technical details for the ETHERCAT Coupler.
Parameters
(AKT-PRB-000-000)
Number of Bus Terminals
64
Digital peripheral signals
512 inputs/outputs
Analog peripheral signals
128 inputs/outputs
Configuration possibility
IDE software or controller
Maximum number of bytes
64 bytes (DP and FMS operation)
128 bytes (DP operation only)
Baud rate (automatic detection)
Up to max. 12 MBaud
Bus connection
1 x D-sub plug, 9-pin with shielding
Power supply
24 V
DC
(-15 % /+20 %)
Input current
70 mA + (total Standard-Bus current)/4, max. 500 mA
Starting current
2.5 x continuous current
Standard-Bus current up to
1750 mA (BK3x00)
Power contact voltage (Up)
Maximum 24 V
DC
Power contact current load (Up)
Maximum 10 A
Recommended fuse (Up)
Maximum 10 A
Electrical isolation
Power contact / supply / fieldbus
Dielectric strength
500 V
rms
(power contact / supply / fieldbus)
Dimensions (H × W )
100 × 51 mm
Weight ~150
g
Permissible ambient temperature
(operation)
0 °C … +55 °C
Permissible ambient temperature
(storage)
-25 °C … +85 °C
Permissible relative humidity
95 % (no condensation)
Vibration / shock resistance
According to EN 60068-2-6 / EN 60068-2-27,
EN 60068-2-29
EMC resistance Burst / ESD
According to EN 61000-6-2 (EN 50082) /
EN 61000-6-4 (EN 50081)
Protection class
IP 20
Installation position
Variable