1.7 Setup
1.7.1 Important notes
Only specialist personnel with extensive knowledge in the areas of electrical engineering /
drive technology are allowed to commission the drive unit of servo amplifier and motor.
DANGER
Deadly voltages can occur, up to 900 V. Risk of electric shock! Check
that all live connection points are safe against accidental contact.
Never undo the electrical connections to the motor when it is live. Risk of
electric shock! The residual charge in the capacitors of the drive can pro-
duce dangerous voltages up to 10 minutes after the mains supply has
been switched off.
Even when the motor is not rotating, control and power leads may be live.
Measure the DC-link voltage and wait until it has fallen below 60 V.
CAUTION
The surface temperature of the motor can exceed 100°C in operation.
Danger of light burns! Check (measure) the temperature of the motor.
Wait until the motor has cooled down below 40°C before touching it.
CAUTION
The drive performing unplanned movements during commissioning can-
not be ruled out.
Make sure that, even if the drive starts to move unintentionally, no danger
can result for personnel or machinery.
The measures you must take in this regard for your task are based on the
risk assessment of the application.
AKM Installation | 1 English
Kollmorgen | kdn.kollmorgen.com | June 2018
25
Содержание AKM
Страница 11: ...1 3 3 Model number description AKM Installation 1 English Kollmorgen kdn kollmorgen com June 2018 11...
Страница 37: ...2 3 3 Typenschl ssel AKM Installation 2 Deutsch Kollmorgen kdn kollmorgen com June 2018 37...
Страница 63: ...3 3 3 Codici dei modelli AKM Installation 3 Italiano Kollmorgen kdn kollmorgen com June 2018 63...
Страница 91: ...4 3 3 Codificaci n de modelo AKM Installation 4 Espa ol Kollmorgen kdn kollmorgen com June 2018 91...
Страница 119: ...5 3 3 Cl de type AKM Installation 5 Fran ais Kollmorgen kdn kollmorgen com June 2018 119...
Страница 138: ...AKM Installation 5 Fran ais 138 Kollmorgen kdn kollmorgen com June 2018...
Страница 141: ...6 2 6 2 1 l l l l IEC 60364 IEC 60664 20 AKM7 AKM8 144 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 141...
Страница 142: ...AKM Installation 6 100 C 40 C PE 60 142 Kollmorgen kdn kollmorgen com June 2018...
Страница 147: ...6 3 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 147...
Страница 161: ...6 6 200 6 6 1 10 60 PE EN 60204 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 161...
Страница 163: ...6 7 6 7 1 900 10 60 100 C 40 C AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 163...
Страница 164: ...AKM Installation 6 6 7 2 1 2 3 4 24 5 6 7 8 9 164 Kollmorgen kdn kollmorgen com June 2018...
Страница 165: ...6 7 3 AKM Installation 6 Kollmorgen kdn kollmorgen com June 2018 165...
Страница 188: ...AKM Installation 8 Dimension drawings Radial axial forces at shaft end 188 Kollmorgen kdn kollmorgen com June 2018...
Страница 196: ...AKM Installation 8 Dimension drawings Radial axial forces at shaft end 196 Kollmorgen kdn kollmorgen com June 2018...
Страница 210: ...AKM Installation 11 Record of document revisions 210 Kollmorgen kdn kollmorgen com June 2018...
Страница 211: ...AKM Installation 11 Record of document revisions Kollmorgen kdn kollmorgen com June 2018 211...