AKD2G-S Installation Manual, Safety 1 | 8 Electrical Installation
8.10.2 Electronic Gearing
AKD2G offers up to 5 feedback channels. Any of these channels may be used as the gearing
command source. The gearing source is selected for each axis using
AXIS#.GEAR.FBSOURCE. Refer to the WorkBench Online Help for more information.
8.10.3 Master-Slave control
Several AKD2G can be connected as slave drives to another AKD2G which acts as a mas-
ter. The slave drives use the master's encoder output signal (EEO, (
# 92)) as command
input and follow these commands (velocity and direction).
8.10.3.1 Master-Slave using X22
The master is configured for EEO2 (
# 92) on X22, the Slave uses X22 for command input.
8.10.3.2 Master-Slave using optional X23 or X41
The master is configured for EEO1 (
# 93) with SFA) on
X41, the Slave uses X23 (or X41 with SFA) for command input.
94
Kollmorgen | kdn.kollmorgen.com | July 2020