AKD Installation | 9 Electrical Installation
9.13 Electronic gearing, Master-slave operation (X9, X7)
It is possible to set up master/slave systems, use an external encoder as a command
encoder, secondary feedback device (dual loop control) or connect the amplifier to a third
party step controller. Depending on the signal voltage level connector X9 (5 V TTL) or X7 (24
V) must be used.
The WorkBench setup software is used for configuration. See the “Feedback 2” screen in
WorkBench for setup. FB2.SOURCE, FB2.MODE, FB2.ENCRES and others are used for
setting up an application with these interfaces.
Connector X9 can be configured as an input or as an output for 5 V (TTL level) signals.
Input modes X9
Output mode
Pulse & Direction, 5 V
Emulated Encoder
Output (A quad B), 5 V
CW/CCW, 5 V
Incremental Encoder
(A quad B), 5 V
Encoder with EnDat 2.2,
5 V
Connector X7, DIGITAL-IN 1/2 can be configured as an input for 24 V signals.
Input modes X7
DIGITAL-IN 1/2
Output mode
Pulse & Direction, 24 V
CW/CCW, 24 V
Incremental Encoder
(A quad B), 24 V
9.13.1 Technical characteristics and pinout
9.13.1.1 Connector X7 Input
Technical characteristics
Floating, reference common line is DCOM7
Maximum signal input frequency: 500 kHz
Sink or Source type connection possible
High: 3.5 to 30 V/2 to 15 mA , Low: -2 to +2 V/<15 mA
Update rate: firmware reads hardware input state every 250 µs
Pin
Pulse/Direction
CW/CCW
Incremental Encoder
9
Pulse
CW
Channel A
10
Direction
CCW
Channel B
1
Common
Common
Common
138
Kollmorgen | kdn.kollmorgen.com | October 2017
Содержание AKD series
Страница 162: ...AKD Installation 9 Electrical Installation Wiring diagram X24 162 Kollmorgen kdn kollmorgen com October 2017 ...
Страница 179: ...9 20 6 CAN Bus Wiring AKD Installation 9 Electrical Installation Kollmorgen kdn kollmorgen com October 2017 179 ...
Страница 214: ... AKD Installation 11 Index 214 Kollmorgen kdn kollmorgen com October 2017 ...