9.12.5 SFD
The diagram below shows the connection of the four wire Kollmorgen SFD feedback system.
When SFD cable total resistance for 5V out (Up) and 5V return (0V) is less than 3.3 Ohm,
then remote sensing is not needed. For typical cable this means remote sensing is not
needed up to 25 m.
Kollmorgen cables are rated up to 50 m with no remote sensing.
Type
FBTYPE
Up
Remarks
Smart Feedback Device
(SFD)
41
5.1 V +/-5%
accuracy 14 bit (0.022°),
resolution 24 bit (2 x 10E-5°)
The pin assignment shown on the SFD end relates to Kollmorgen motors.
AKD Installation | 9 Electrical Installation
Kollmorgen | kdn.kollmorgen.com | October 2017