AKD PROFINET | 4 Installation and Setup
4.2 PROFINET Onboard
Connection to the PROFINET Network via X11.
Connect the service interface (X11) of the drive to an Ethernet interface on the PROFINET
Master directly or via a network switch,
while the supply to the equipment is switched
off.
Confirm that the link LED on the AKD (the green LED on the RJ45 connector) and on your
Master or Switch are both illuminated. If both lights are illuminated, then you have a good
electrical connection.
PROFINET RT and WorkBench can operate simultaneously if a switch is used.
4.2.1 LED functions
The communication status is indicated by the built-in LEDs.
Connector LED#
Name
Function
X11
LED1 IN port Link
ON = active, OFF= not active
LED2
RUN
ON = running, OFF = not running
4.2.2 Connection technology
You can connect to the PROFINET network using RJ-45 connectors. Use standard Cat. 5
Ethernet cables for either connection configuration.
4.2.3 Network Connection Examples
14