Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself  and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

Aft er unpacking the unit, carefully inspect unit for any damage that may have occurred during 

transit. Check for any loose, missing, or damaged parts.

Unpacking

High Capacity Air Conditioner 

(For Indoor & Outdoor)

K6HK144BBA2ACA0 

K6HK144BEA2ACA0

Figure 1

Owner’s Manual

Specifi cati ons

K6HK144BBA2ACA0 / K6HK144BEA2ACA0

Model No.

Power Supply 

Ph-V-Hz

Cooling Capacity 

Btu/h

Power Con-

sumpti on Watt s

Rated Current 

Amps

K6HK144BBA2ACA0

 3Phases - 

220V - 60Hz 

144,400

18kW

57A

K6HK144BEA2ACA0

3Phases - 

460V - 60Hz

144,400

21.5kW

27A

Model No.

Weight (Net / Gross) 

Lbs(kg)

Ambient tempera-

ture range  °F( °C)

Dimensions  

W x D x H - in. (mm)

K6HK144BBA2ACA0

1168/1245lbs.

(530/565kg)

64~113

(18~45)

34.3 x 75 x 71

(870 x 1904 x 1801 )

K6HK144BEA2ACA0

KOLDWAVE

 Portable Air Conditi oners are specialized for 

“SPOT COOLING” where central cooling is impracti cal. 

KOLDWAVE 

air conditi oners can also be used in enclosed areas 

just like conventi onal air conditi oners. Simple digital controller 
and self-diagnosti c functi ons allow users to easily operate 
the unit. Built-in Caster wheels enable users to move the 
unit without any hassle. The unit can be installed in 5 minutes 
and does not require any extra materials or certi fi ed technician 
for installati on. 

KOLDWAVE

 Portable Air Conditi oner, anywhere, everywhere. 

Plug-and-Go!

Descripti on

Содержание K6HK144BBA2ACA0

Страница 1: ...sumption Watts Rated Current Amps K6HK144BBA2ACA0 3Phases 220V 60Hz 144 400 18kW 57A K6HK144BEA2ACA0 3Phases 460V 60Hz 144 400 21 5kW 27A Model No Weight Net Gross Lbs kg Ambient tempera ture range F...

Страница 2: ...integrated with PUMP DOWN function PUMP DOWN function keeps compressor running for certain time to protect compressor and other crucial parts before the unit or compressor is turned off PUMP DOWN func...

Страница 3: ...operate the unit with wet or damp hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit near flammable substances or vapors such as alcohols pesticid...

Страница 4: ...upright position on an even flat surface There must not be any objects or walls within 24 inches 60 cm from the unit 22 Halt the unit immediately if abnormal noise or odor is detected Contact your loc...

Страница 5: ...OMPONENT PARTS Front and Right Side View Controls Hot Air Exhaust Electrical Panel Caster Condensate outlet I BOLT Cold Air Inlet Cold Air Inlet Filter Emergency Stop Controls Figure 2 Figure 3 Figure...

Страница 6: ...and pinches in the ducting 3 Verify the termination points are not restricted meaning no objects are directly in front of the termination The Return Air In duct connection is labeled AIR IN The conne...

Страница 7: ...t dust oil water or any other foreign material The unit is equipped with an approved NEMA plug configuration The appropriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION F...

Страница 8: ...or 1 seconds Two digits on CURRENT TEMP indicate hour s and two digits on TARGET TEMP indicate minutes Set desired off time by pressing SET TEMP BUTTONS 5 ALARM Alarm indicator lights blinks and indic...

Страница 9: ...nd are displayed when abnormal operation occurs 10 EMERGENCY STOP Emergency stop button immediately halts the operation 1 Press the red button Unit stops 2 Inspect the unit 3 Rotate the red button clo...

Страница 10: ...ion Plate the purchase date purchase location serial number and war ranty period in the table below Also attach your purchase receipt as proof of purchase to this instruction manual for future referen...

Страница 11: ...nd keep this manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is activated if abnormal operation occurs and a code is displayed...

Страница 12: ...nnection Re connect the power cable to the correct power source Drain pump Applicapable for unit with drain pump Defective drain pump Improper water circulation Check the hose connection from drain pu...

Страница 13: ...a qualified service agent Abnormal temperature sensor value TH1 Evaporator coil temperature sensor has a loose or broken connection Contact a qualified service agent Abnormal temperature sensor value...

Страница 14: ...CP T 1 S 1 COM CO FUSE FUSE HIGH PRESSURE SWITCH E PBS R S T R S T R 2 S 2 T 2 S S 2A T 2A MC 2 OCR 2 R 3 S 3 T 3 R T COND MOTOR S R 3A S 3A T 3A MC 3 OCR 3 R 4A S 4A T 4A R T S No 1 EVA MOTOR T CP CP...

Страница 15: ...R T COMP FND PS HP COM COM EXT FU FT CO COM R COM L H COM CP N 1 L 1 COM CO Power Remote Control Option EXT COM FUSE FUSE HIGH PRESSURE SWITCH PHASE PROTECTOR C CM B NC A NO R L1 S L2 T L3 TR 220V E...

Страница 16: ...perly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes after unit is turned off before tu...

Страница 17: ...17 Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0...

Страница 18: ...e Portable Air Conditioner Technical Support at 413 564 5520 Please have the following information available BEFORE calling the Technical Support Department a Your name and address b The serial number...

Страница 19: ...19 Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0 For Koldwave warranty please visit http koldwave com html literature asp...

Страница 20: ...Owner s Manual K6HK144BBA2ACA0 K6HK144BEA2ACA0 Printed in April 2019 KOLDWAVE Sterling heating div Farmville 3576 S Fields st Farmville NC 27828 0809 USA PH 252 753 1921 Fax 252 753 1953 www koldwave...

Отзывы: