Remote Operations 

The included remote is a universal remote control. Some functions may be found on the remote 
that this model of air conditioner does not have. If an unavailable function is selected the unit will 
continue operating under its current running status. Use the remote control to change modes, fan 
speed, timer, and temperature settings as well as to set sleep mode. 
 
 
 

 

 

 

Button 

Function 

On / Off 

This button powers the unit on or off. 

Mode 

This button allows you to cycle through the 
following modes: Auto, Cool, Energy Saver, 
Fan Only, and Dry. 

Fan 

This button allows you to cycle through the 
following fan speeds: automatic, Fan 1, Fan 2, 
and Fan 3. 

I Feel 

This button is used to enable I Feel mode.  
While in I Feel mode, the remote will send the 
ambient temperature value to the air 
conditioner every 10 minutes. Fan and 
temperature adjustments are then made 
according to the temperature measured at the 
remote’s location. 

Sleep 

This button is used to enable Sleep mode.  
Within 2 hours after the Sleep mode is 
activated, the set temperature will increase by 
2

 (1

℃) 

per hour. For the duration of Sleep 

mode, the set temperature will increase by 4

℉ 

(

2

℃)

. Press this button again to turn off Sleep 

mode. Sleep mode is available in Cool, Energy 
Saving, and Dry modes. 

Timer 

This button is used to enable the timer. Press it 
twice to cancel the programmed Auto 
Start/Start time. 

Increase 

This button increases the set temperature, or 
the time when the Timer is enabled. 

Decrease 

This button decreases the set temperature, or 
the time when the Timer is enabled. 

 

Note: Be careful not to drop the remote control. Do not place the remote control in a location 
exposed to direct sunlight. 

Содержание CAC8000W

Страница 1: ...ndow Air Conditioner Owner s Manual For more information on other great EdgeStar and Koldront products on the web go to https www edgestar com To use the EdgeStar self diagnostic tool go to https supp...

Страница 2: ...his unit near flammable gases combustibles or in close proximity to heating appliances During operation do not remove any part of the outside casing Electrical Requirements A 115 volt 103 5 minimum 12...

Страница 3: ...hould trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR WINDOW AIR CONDITIONER IF TH...

Страница 4: ...nit for Installation 4 Installing Air Conditioner Into a Slider Window 8 Installing Air Conditioner Into a Casement Window 9 CONTROL PANEL OPERATIONS 10 Using the Control Panel 10 REMOTE OPERATIONS 13...

Страница 5: ...back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warran...

Страница 6: ...2 Parts Identification Side View Front View CAUTION Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Страница 7: ...choose one that is near an electrical outlet that will be able to provide sufficient power to your unit See the power requirements listed on the product label printed on the side or the back of your...

Страница 8: ...rt brace and test again 2 Measure 8 11 16 from the window jamb and lightly draw a line in pencil NOTE When choosing your window make sure power supply cord is within 6 feet of a grounded 3 prong outle...

Страница 9: ...sealing strip on the inner track 5 Securely attach a siding protection board to the side of the house 6 Place the window platform with the platform tab against the inside of the window track Fasten t...

Страница 10: ...ng three 8x3 8 screws item 17 in the parts supplies list per channel When fastening the screws start with the top screw and make sure that the curved ends on the long end of the channel face back towa...

Страница 11: ...4 screws from the front panel 2 Press firmly on both sides of the metal case close to the front panel and pull the front panel out and up to release it from the case 3 Remove the four 4 screws on the...

Страница 12: ...he window does not fit snugly against the window panel frame it can be secured with screws Using the partially plugged holes in the window panel frame drill 1 8 pilot holes for the screws Secure the w...

Страница 13: ...ir Conditioner Into a Casement Window Follow the steps listed below to install the air conditioner into the window 1 Using two 2 or more persons safely lift the air conditioner into the windowsill on...

Страница 14: ...9 64 diameter pilot holes in the side window jambs Secure the side channels using two 8 32x3 4 self threading screws 4 Replace the front panel by reversing the steps in the Remove the Front Panel sect...

Страница 15: ...set temperature cannot be adjusted It will start automatically at a speed calibrated to the actual room temperature To Operate in Cool Mode When the unit is set to Cool mode it will cool the room to...

Страница 16: ...s and then one 1 hour increments up to 24 hours The selected time will register in five 5 seconds and the system will automatically revert back to display the previous temperature setting or room temp...

Страница 17: ...e will send the ambient temperature value to the air conditioner every 10 minutes Fan and temperature adjustments are then made according to the temperature measured at the remote s location Sleep Thi...

Страница 18: ...switch the temperature display between Celsius and Fahrenheit Light Function While the unit is either off or on you may hold the and Fan buttons simultaneously for three 3 seconds to turn the LED disp...

Страница 19: ...n 2 Grasp the filter pull up and out 3 Wash the filter using liquid dishwashing detergent and warm water Rinse the filter thoroughly 4 Gently shake excess water from the filter Be sure the filter is t...

Страница 20: ...by the fan Gurgle Hiss Gurgling or Hissing noise may be heard due to refrigerant passing through the evaporator during normal operation Vibration The unit may vibrate and make noise because of poor wa...

Страница 21: ...a warmer climate Minimize the heat sources direct sunlight computers servers people etc in the room Close all windows and doors Use the unit in a contained room For example a room with four walls and...

Страница 22: ...el cold enough Room temperature is below 61 17 Cooling will not occur until room temperature rises above 61 17 Temperature sensor behind the front grill and air filter is touching the cold evaporator...

Страница 23: ...ner turns on and off frequently Dirty air filter air restricted Clean air filter Outside temperature is extremely hot Set FAN speed to a Higher setting to push more air through the coils Noise when un...

Страница 24: ...roduct Casement Window Air Conditioner Model CAC8000W Voltage Frequency 115V 60Hz Cooling Capacity BTUs 8000 Current 6 5A Color White Refrigerant R410A 18 34 oz Timer 24 Hour Dimensions W x D x H 14 1...

Страница 25: ...on or commercial use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 24 month period Products that have been modified to perform...

Отзывы: