3-2 Adjustment of engorgement of breast

The hardness and shape of breasts can be adjusted by inflating and deflating the breast bags.
1.   Attach the connector of the air pump to the two-way cock.

 2.  Turn the handle of the two-way cock to open; close the valve of the air pump and inject the air.

  * To reduce the volume of the air, loosen the valve of the air pump to let the air out.

  * Press the air pump for about 8 to 10 times, or 15 times at the maximum.
  * Be careful, as the bag may be damaged when it is inflated too much.

 

 

 

 
 
 
 
 
 
 
     
 
 

 

 

 

 

 
 
 
 
 
 
 
     
 
 

 

 

 

 

 
 
 
 
 
 
 
     
 
 

 

Connect the lure lock to the connecting 

port of the two-way cock.

Close

Open

Normal condition

Engorgement

Содержание LM-113

Страница 1: ...n Manual Thank you for purchasing our products Please read this instruction manual carefully to ensure the correct use of the products and store it in a safe place for easy access KOKEN CO LTD 1 4 14...

Страница 2: ...irect sunlight and ultraviolet light 6 Never use oil based ink pencils chalk and paint on the model They will soak into the model and cannot be erased 7 This model can be neither dry cleaned nor machi...

Страница 3: ...ntents 1 Outline and Features 2 Names of Parts and Structure 3 Handling Instructions KOKEN Postpartum Breast Care Model 4 Handling Instructions Latch on mask for KOKEN Baby 5 Instructions for Care 6 S...

Страница 4: ...an appropriate latch of babies and breastfeeding posture 4 By taking an appropriate breastfeeding position and achieving a latch at an appropriate position users can confirm the condition of an appro...

Страница 5: ...s of Parts and Structure KOKEN Postpartum Breast Care Model 1 Name of the part Quantity Harness Air pump Baby powder Protective board Breast bag right and left Instruction manual this brochure 1 1 1 1...

Страница 6: ...or KOKEN Baby KOKEN Breastfeeding Simulation Set The set consists of KOKEN Postpartum Breast Care Model and Latch on mask for KOKEN Baby Name Quantity Latch on mask for KOKEN Baby Instruction manual t...

Страница 7: ...to the chest of the wearer and then fasten the shoulder belts 2 Fasten the back belt When the back belt is loose for instance when the wearer is thin fasten the supplementary hook and loop fastener 3...

Страница 8: ...dle of the two way cock to open close the valve of the air pump and inject the air To reduce the volume of the air loosen the valve of the air pump to let the air out Press the air pump for about 8 to...

Страница 9: ...4 Secure the air tube with the hook and loop fastener under the arm so that the tube does not get in the way To change the hardness deflate the bag once and then inflate it again After finishing the...

Страница 10: ...ctive board and lift the flap of the harness Do not discard the protective board by mistake 2 Slowly remove the breast bags from the opening on the backing sheet Do not pull with force or hook with sh...

Страница 11: ...o that they come out downward 3 Put the protective board back 4 Confirm the position of the breast bags by looking at the model from the breast skin side and adjust the bags so that they look natural...

Страница 12: ...e mask is sticky and hard to attach apply baby powder inside the mask and the head of KOKEN Baby 2 Fasten the hook and loop fastener on the back of the head 4 2 How to use By using it with KOKEN Postp...

Страница 13: ...arts are heavily soiled remove the breast bags and the protective board hand wash the rest by gently pressing with regular washing detergent in lukewarm water up to 30 C Handle the breast skin part as...

Страница 14: ...Breast Care Model Latch on mask for KOKEN Baby Length Width Height Weight Approximately 15 cm Approximately 13 cm Approximately 12 cm Approximately 96 g Name of the part Material Harness Breast skin B...

Отзывы: