Содержание K30 Series

Страница 1: ...1 5 1 0 530 3 4 3 4 4 3 4 1 35...

Страница 2: ...74 MICRO COMPUTER Digital PID Controller User s Manual K30 SERIES PID CONTROLLER...

Страница 3: ...se heed the cautions and warnings listed in this manual The contents of the manual may be changed without notice The product is designed to be used installed on a control panel This manual is copyrigh...

Страница 4: ...tric shock 7 Do not attempt to disassemble modify and repair 1 Please conduct an inspection when water has entered the product It may cause short circuits fires and malfunction 2 This controller shoul...

Страница 5: ...ion procedures 9 Flow chart Parameter structure 10 Setting mode 11 Alarm ALARM1 2 setting 12 Details explanation of primary function 12 1 Auto tuning AT function 12 2 Manipulated variable Mvn check mo...

Страница 6: ...No option Basic function 4 K34 SERIES 48 W 48 H 99 D Option 0 1 2 3 7 K37 SERIES 72 W 72 H 77 D Option 0 3 9 K39 SERIES 96 W 96 H 77 D No option Basic function Control mode Code Description Remarks S...

Страница 7: ...m output 2 Ex K34 S30 K37 SERIES Basic function 0 RELAY output 1 Alarm output 2 Basic function Option code 0 No option SCR 4 20mA SSR Voltage pulse 1 3 D I SV2 3 RET 4 20mA Retransmission Ex K37 S30 K...

Страница 8: ...11 199 9 400 0 C W5 12 0 2300 D W3 13 0 2400 RTD JPt100 JIS KS 20 199 9 500 0 22 200 500 Pt100 DIN IEC 21 199 9 640 0 23 200 640 Voltage VDC mVDC 0 100 mV DC 33 0 100mV DC 10 20 mV DC 32 10 20 mV DC 1...

Страница 9: ...fault value at the point of manufacture SCR output of PID control 4 20mA current output Output setting number 2 This setting is used mainly with thyristor power regulator TPR modules and is capable of...

Страница 10: ...s 45 0 5 92 0 5 Min 20 Min 30 K32 K33 48 96 Panel cutouts Unit mm 2 K33 96 48 mm Dimensions 3 K34 48 48 mm Dimensions Unit mm 45 0 0 5 45 0 0 5 Min 17 Min 17 K34 48 48 Panel cutouts 3 Dimensions and p...

Страница 11: ...83 4 K37 72 72 mm Dimensions 5 K39 96 96 mm Dimensions Unit mm Unit mm 68 0 5 68 0 5 Min 20 Min 30 K37 72 72 Panel cutouts K39 96 96 Panel cutouts 92 0 5 92 0 5 Min 20 Min 30 PID CONTROLLER...

Страница 12: ...s shown on Figure 2 Bore a hole in the panel referring to the panel cutouts on the previous page Insert this device into the front of the panel Insert 2 brackets one each on the B K holes on the top a...

Страница 13: ...85 4 Terminal arrangements and wirings K32 K33 1 K32 48 96 mm K33 96 48 mm 2 K34 48 48mm K32 K33 Basic type K32 S0x K33 S0x OPTION Basic type OPTION Option 1 K34 S1x Option 3 K34 S3x PID CONTROLLER...

Страница 14: ...R SCR output mode Terminal 6 7 RET Retransmission 4 20mA or for power of sensor SPS DC 15V Terminal 8 9 Power supply terminal Terminal 11 12 Alarm1 output terminal Terminal 13 14 Alarm2 output termina...

Страница 15: ...ing to SG PID algorithm Control output Relay 1c 250VAC 3A resistive load Electrical life 100 000 min PID output or ON OFF output Voltage S S R DC15V 25mA Built in short protection circuit Voltage puls...

Страница 16: ...or Auto tuning lamp Flash every 0 5 second during auto tuning Set value display Display the set value codes and modes Control output lamp Lights when the control output is ON SV 2 display lamp Lights...

Страница 17: ...nly when SSR 1 or SCR 2 is chosen as the output mode Alarm 1 output will be in main relay Refer to page 8 for details 3 Initial display on power supply K34 SERIES basis Model Name Option indication Ou...

Страница 18: ...made When the input type is changed all other parameters set values are reverted to their factory default 3 Select the desired set value SV 4 Please set auto tuning or P I D values to suit the operat...

Страница 19: ...est scale On voltage input Type of alarm 1 Type of alarm 2 Hysteresis of alarm 1 Hysteresis of alarm 2 Delay time of alarm 1 Delay time of alarm 2 Retransmission type or SPS selection Set of menu lock...

Страница 20: ...control 20 0 SV1 2 Integral time I OFF 1 6000 sec PID control 240 sec SV1 2 Differential time D OFF 1 6000 sec PID control 60 sec SV1 2 Manual reset MR 5 0 105 0 Integral time OFF 50 0 Cycle Time P I...

Страница 21: ...tion in Voltage input mode _DPP 0 3 Voltage or 4 20mA input mode only 1 Free scale upper limit set voltage input mode 1999 9999 But SL H SL L Decimal point positioning by _DPP 100 0 Free scale lower l...

Страница 22: ...1 2 Setting The K30 series has two separate alarm outputs and in the setting group alarms may be chosen among 21 types and the dead band hysteresis for the alarm output may be set Please find the alar...

Страница 23: ...tion Inverted 07 Upper Lower limit deviation 17 Upper Lower limit deviation with hold 08 Upper Lower limit deviation in range 18 Upper Lower limit deviation in range with hold 21 Loop break alarm LBA...

Страница 24: ...the keys while auto tuning is in progress AT operation start 0 5 second AT stop by perforce 0 5 second SET SET AT command lamp flash every 0 5sec Do not use auto tuning under below Process Rapid cont...

Страница 25: ...mode it can be utilized for detection E g output is generated if there are problems with control unit and other problems or can be used for heater disconnection How to set up Description of operation...

Страница 26: ...value PV set value SV output amount MV or sensor power supply SPS may be chosen and the output will be generated in direct current of 4 20mA SPS is DC15V 25mA Retransmission type or SPS selection PV...

Страница 27: ...elect SHORT OFF Block external contact signal Can select under inside menu only Please use a non voltage contact relays switches for direct input If a non contact device such as a semiconductor are us...