Kohler Rada Tripoint-F 2.1658.011 Скачать руководство пользователя страница 2

2

1074257-W2-D

Installations must comply with all Local/National Water Regulations/Bye-laws 

(Scotland), Building and Plumbing Regulations.
Installation must be carried out in accordance with these instructions, and must be 

conducted by designated, qualified and competent personnel.

Disinfectants:

 In applications where system chemical disinfection is practised, 

chlorine can be used (calculated chlorine concentration of 50 mg/l [ppm] maximum in 

water, per one hour dwell time), at service interval frequency. Such procedures must 

be conducted strictly in accordance with the information supplied with the disinfectant 

and with all relevant Guidelines/Approved Codes of Practice. If in any doubt as to 

the suitability of chemical solutions, refer to Kohler Mira Limited, or your Local Agent.
When the battery has reached the end of its serviceable life, make sure the battery 

is disposed of in a safe manner, in accordance with current local authority recycling, 

or waste disposal policy.

IMPORTANT SAFETY INFORMATION

DESCRIPTION

The Rada Tripoint-F sensor deck mounted washbasin tap complies with all relevant 

directives for CE marking. The Tripoint-F sensor tap can be installed as an adjustable, 

a pre-set non-adjustable or for pre-mixed supply for most commercial applications.

SPECIFICATIONS

Pressures

Maximum Static Pressure

1000 kPa (10 bar)

Minimum Pressure Loss

200 kPa (2 bar)

Flow Rates and Times

Minimum Flow Rate (Flow Regulator Fitted)  6 L/min (300 kPa (3 bar))

Maximum Flow Period

2 minutes ±3 seconds

Intelligent After Flow Period

3 seconds ± 2 seconds

Temperatures

Maximum Hot Water

70 °C

Electrical

Power Supply

6 V lithium battery 2CR5

Sensor Recognition Range

Optimal preset

Approvals

Noise Class

I (ISO 3822)

IP Rating (Protection Class)

IP67

Guarantee

We guarantee this product against any defect in materials or workmanship for a period of 

one year

 from the date of purchase. For terms and conditions refer to the back cover.

Содержание Rada Tripoint-F 2.1658.011

Страница 1: ...1 11074257 W2 D Tripoint F PRODUCT MANUAL IMPORTANT Installer This Product Manual is the property of the customer and must be retained with the product for maintenance and operational purposes...

Страница 2: ...tery is disposed of in a safe manner in accordance with current local authority recycling or waste disposal policy IMPORTANT SAFETY INFORMATION DESCRIPTION The Rada Tripoint F sensor deck mounted wash...

Страница 3: ...d are included Note All dimensions are nominal and in millimetres Documentation 1 x Product Manual 1 x Instruction Sticker 1 x Temperature Plug Cover 2 x Wall Plugs 2 x Fixing Screws 2 x Cable Ties 1...

Страница 4: ...Options Note Do not install opposite a mirror Adjustable temperature outlet Set for fixed temperature outlet Using pre mixed temperature supply Note Turn to full cold and block hot inlet Warning Inle...

Страница 5: ...5 11074257 W2 D Warning Battery must be installed as shown Failure to do so will invalidate warranty Minimum 30 mm Maximum 37 mm 2 1 3...

Страница 6: ...6 1074257 W2 D 4 Important IMake sure that the flats on the connectors line up before you install the cable...

Страница 7: ...7 11074257 W2 D Operate the tap and rotate the lever to adjust the water to your required temperature 5 This completes the fitting of the Rada Tripoint F sensor tap OPERATION...

Страница 8: ...F sensor tap for fixed temperature flow Operate the tap until the temperature of the water flow is stable and follow steps 1 to 4 to set the fixed water temperature Operate the tap and check the wate...

Страница 9: ...late the water supplies and operate the tap to release pressure and to assist the draining of residual water before any maintenance is carried out Cleaning the Filters MAINTENANCE Changing the Flow St...

Страница 10: ...ce the battery Cleaning The tap should ONLY be cleaned using a mild washing up detergent or soap solution and wiped dry with a soft cloth Note To isolate the sensor place cleaning cover over the senso...

Страница 11: ...1658 020 Battery 1658 021 Temperature Control Handle 1658 022 Inlet Hose 1658 023 Product Manual 1658 025 3 8 Adaptor Check Valve and 3 8 to 1 2 Adaptor 1658 026 Flow Straightener M24 x 1 1658 027 Cle...

Страница 12: ...ter or electrical supply waste and isolation issues Compensation for loss of use of the product or consequential or indirect loss of any kind Damage or defects caused if the product is repaired or mod...

Отзывы: