FAULT DIAGNOSIS
Symptom
Cause / Rectification
Continuous flow from the tap
Solenoid valve damaged / Replace
Reduced flow from the tap
Blocked filter or aerator / Refer to ‘Maintenance’
section
No flow from the tap
Check the water supply and rectify
The sensor is covered, dirty, disconnected or
damaged / Clean, check the connections or replace
the sensor
The solenoid valve is damaged / Replace the
solenoid valve
The battery is flat / Replace the battery
Cleaning
The tap should ONLY be cleaned using a mild washing up detergent or soap solution
and wiped dry with a soft cloth.
Note!
To isolate the sensor, place cleaning cover over the sensor.
Cleaning Cover
Change the Battery
When the 2CR 6Volt battery has expired,
battery replacement should be carried out
with care.
DO NOT
force the battery into the battery
box. Observe the shape of the battery box.
The battery should easily slip in and out of
the battery box.
DO NOT
force the plug into the battery box
socket in reverse. Follow the alignment line
on the plug.
Warning!
The
battery must be
inserted to match
the shape of
battery case.