background image

These instructions must be left with the user

Installation Guide

Mira Jump

7.5, 8.5, 9.5 and 10.8 kW Electric Shower

1224546-W2-D

For SPARES, ADVICE 

or REPAIRS

Please call us on

0844 571 5000

(UK Only)

Mira Sprint

8.5, 9.5 and 10.8 kW Electric Shower

COMMISSIONING

SERVICING

© Kohler Mira Limited, May 2017

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifications without notice.

FM 14648

CUSTOMER SERVICE

The guarantee applies solely to the original installation under normal 

use and to the original purchaser only. The product must be installed 

and maintained in accordance with the instructions given in this guide. 
Servicing must only be undertaken by us or our appointed representative. 

Note!

 If a service visit is required the product must be fully installed and 

connected to services.
Repair under this guarantee does not extend the original expiry date. 

The guarantee on any replacement parts or product ends at the original 

expiry date

For shower fittings or consumable items we reserve the right to supply 

replacement parts only.

The guarantee does not cover:

Call out charges for non product faults (such as damage or performance 

issues arising from incorrect installation, improper use, inappropriate 

cleaning, lack of maintenance, build up of limescale, frost damage, 

chemical attack, corrosion, system debris or blocked filters) or where no 

fault has been found with the product.
Water or electrical supply, waste and isolation issues.
Compensation for loss of use of the product or consequential or indirect 

loss of any kind.

Damage or defects caused if the product is repaired or modified by persons 

not authorised by us or our appointed representative.
Accidental or wilful damage
Products purchased ex-showroom display.

What to do if something goes wrong

If your product does not work correctly refer to this manual for fault diagnosis 

and check that it is installed and commissioned in accordance with our 

instructions.

If this does not resolve the issue, contact us for help and advice.

Extended Guarantees

A selection of protection plans are available that enable you to cover repair 

bills (excludes Eire). Ring 01922 471763 for more details.

Guarantee

Your product has the benefit of our manufacture’s guarantee which starts from 

date of purchase. This guarantee only applies in the United Kingdom and 

Republic of Ireland. To activate this guarantee, please return your completed 

registration card, visit our website or free phone 0800 0731248 within 30 days 

of purchase (UK only).

Within the guarantee period we will resolve defects in materials or 

workmanship, free of charge, by repairing or replacing parts or product as 

we may choose.

This guarantee is in addition to your statutory rights and is subject to 

the following conditions:

Helpdesk Service -

 Contact our Customer Services Team for 

product advice, to purchase spare parts or accessories or to set 

up service visit. You can contact us via phone or e-mail - contact 

details below. Please provide your model name, power rating (if 

applicable) and date of purchase.

Mira Showers Website (www.mirashowers.co.uk)

Visit our website to register your guarantee, download user 

guides, diagnose faults, purchase our full range of accessories 

and popular spares, or request a service visit.

Spares and Accessories -

 We hold the largest stocks of genuine 

Mira spares and accessories. Contact us for a price or visit our 

website to purchase items from our accessory range and popular 

spares. (Only available in the United Kingdom).

Service/Repairs -

 No one knows our products better than our 

nationwide team of Service Technicians. We can carry out service 

or repair work to your product both during and after the guarantee 

period (Only available in the United Kingdom and Republic of 

Ireland). Ask about our fixed price service repairs.

To Contact Us

0844 571 5000

Fax: 

01242 282595

E-mail: 

www.mirashowers.co.uk/contactus

Mira Customer Services Dept
Cromwell Road, Cheltenham, 
Gloucestershire 
GL52 5EP

To Contact Us: Eire Only

01 531 9337

E-mail: 

[email protected]

WARNING

There are no user serviceable parts inside the shower.

Servicing of the shower must only be carried out by qualified, 

competent personnel following the instructions provided in this 

guide and those provided with any spare part. 

Before replacing any parts, ensure that the underlying cause of 

the malfunction has been resolved.
Cleaning the Inlet Filter
Warning! 

Isolate the electrical and water supplies before removing 

the cover.
Remove the cover.

Remove the elbow from the 

inlet connector.

Note! 

Depending on your 

installation it may be necessary 

to remove the shower from the 

wall to allow filter removal.

In this case isolate all supplies 

and follow steps 6 - 8 in reverse 

order as detailed in section: 

‘INSTALLATION’

.

Inlet Filter

Inlet 

Connector

Prise the filter from the inlet

connector assembly. 

Rinse the filter under a 

running tap to remove 

any lodged particles. If 

necessary, use a kettle 

descalent in accordance 

with the manufacturer’s 

instructions. Refit the inlet 

filter and follow steps 7 and 10 

as described in section:

 ‘INSTALLATION’.

Note! 

If the shower was removed from the wall, steps  

 

6, 7, 8 and 10 will need to be followed as described in section: 

‘INSTALLATION’.

Follow the steps detailed in section: 

‘COMMISSIONING’ 

to prepare 

the shower for use.

No water or very 

low flow rate

The heater tank is 

excessively scaled

Replace the heater

tank assembly

The inlet filter is

blocked

Clean the inlet filter

The fuse is blown

or the MCB / RCD has 

been tripped, indicating 

a possible electrical 

fault; for example, 

heater tank element 

failure

Switch on the power at

the double pole switch

The on / off switching 

assembly is faulty

Replace on / off switching 

assembly

The start / stop switch 

is faulty

Replace start / stop switch

The solenoid coil is 

faulty

Replace solenoid coil

Water leaks from 

the bottom of the 

case near the 

outlet and there is 

no flow from the 

showerhead

The pressure relief 

valve in the tank has 

been triggered (usually 

due to a blocked 

outlet),  when the relief 

valve operates a small

rubber ball is ejected

Resolve the blocked

outlet and replace the 

heater tank assembly

The water cannot 

be turned off

The on / off switching 

assembly is faulty

Replace on / off switching 

assembly

The start / stop switch 

is faulty

Replace start / stop switch

The supply pressure 

is below the minimum 

required

Check the static water 

pressure. Note that the 

static water pressure may 

fall below the minimum 

requirement when other 

appliances are drawing 

water, for example the 

dishwasher or the washing 

machine

Adjust temperature as required. 

Note!

 Flow rate will reduce 

when temperature setting is 

increased.

Temperature will rise further.

Turn power control to High.

Temperature will rise slightly.

5 - 10 secs

COLD

HOT

10

9

5 - 10 secs

COLD

HOT

7

8

Water flows freely within a few 

seconds, temperature remains 

cool

Turn power control to Eco.

COLD

0 - 15 secs

HOT

Push START/STOP button.

Switch on the electrical supply.

5

6

4

3

1

2

Turn temperature control to the 

cold position.

Turn power control to low.

Use the terminal block location 

that is most appropriate for 

your installation i.e. If the 

electric supply is on the right 

hand side then use the right 

hand terminal block.
Strip back sufficient outer 

cable insulation to enable 

routing to the terminal block. 
Fit an earth sleeve to the 

earth wire.
Insert the wires into the 

terminal block.
Tighten the screws in the 

terminal block, ensure the 

wires are secure and tight.

For falling or rising supplies 

the cover has thinned sections 

on the top and bottom that can 

be removed to allow entry of 

the supply pipe and electrical 

cables.

Cover

Screw

Screws

Thinned 

Section

Ensure the earth bonding complies with relevant regulations.

L

  

(Live) = Brown wire

 

(Protective Earth) = Green /Yellow sleeved wire

N

  

(Neutral) = Blue wire

8

Ensure the control dials are 

aligned with the spindles and 

replace the cover.
Tighten the three cover 

screws.

Do not

 use alternative screws 

to secure the cover. This can 

cause internal damage to the 

appliance.

Do not seal around the back of appliance

.

Install the shower fittings (Refer to the Shower Fittings 

Installation and User Guide packed with the product).

The shower must be commissioned before use, please 

refer to section: 

‘COMMISSIONING’

.

This completes the installation.

9

10

11

12

13

Terminal 

Block (LH)

Terminal 

Block (RH)

Warning!

 There are no user serviceable components beneath the 

cover of the appliance. In the event of a malfunction of the shower, 

the troubleshooting information below provides details on possible 

causes and remedies that may be carried out by qualified, competent 

personnel. Non-qualified personnel should refer to the fault diagnosis 

section in the users guide.

FAULT DIAGNOSIS

Symptom

Possible Cause

Possible Remedy

No hot water from 

the shower, with

the controls in 

ECO/HIGH

position

Insufficient water 

supply pressure

Contact local water 

authority

Failure of the 

microswitch or thermal 

switch

Check the continuity

of the switches, using

a suitable continuity

measuring device.

Replace the switches as 

necessary

An internal wiring 

connection has failed

Check the integrity of the 

internal wiring

One of the heater tank 

elements has failed

Replace the heater tank 

assembly

Switch assembly fault

Replace On / Off switching 

assembly

The shower 

temperature

cycles between 

hot and cold with 

power control in 

ECO/HIGH

The hose or

showerhead is

blocked

De-scale showerhead, 

check hose for kinks or 

damage and replace if 

necessary. Refer to the 

User Maintenance section 

of the user guide

The temperature is 

set too high. This is 

causing the thermal 

switch to turn off the 

heating element to 

reduce the water 

temperature

Turn the temperature

control anticlockwise

to reduce the water

temperature or turn the 

power control to ECO.

DO NOT TAMPER with 

the thermal switch

Turning the 

temperature 

control does not 

affect the water 

temperature

The flow regulator is 

faulty

Replace the heater tank 

assembly

The hose or

showerhead is

blocked

De-scale showerhead, 

check hose for kinks or 

damage and replace if 

necessary. Refer to the 

User Maintenance section 

of the user guide

No water or very 

low flow rate

The hose or 

showerhead is

blocked

De-scale showerhead, 

check hose for kinks or 

damage and replace if 

necessary. Refer to the 

User Maintenance section 

of the user guide

The incoming water 

supply stop valves, or 

the appliance isolating 

valve is closed

Open the stop/isolating

valve completely

Insufficient water

supply pressure

Contact the local water

authority

Power LED does 

not illuminate 

when the pull cord 

is operated

Electrical supply failure 

(MCB, pull cord etc.)

Check electrical supply

Power LED faulty

Replace the wiring loom

Note! 

A slight hissing sound may be heard from the shower 

during operation. High mains water pressure and high shower 

temperatures will affect the tone. This is quite normal in use.

A small amount of water may 

continue to drain over a few 

minutes.

13

11

12

Switch off the electrical supply.

Push START/STOP button.

WIRING DIAGRAM

ACCESSORIES

Genuine Mira accessories can be purchased direct from Customers 

Services (our contact details can be found on the back cover of this 

guide) or from approved stockists or merchants.

Inlet Pipe Accessory

1788.443

Designed to simplify the 

retrofitting  of  a  Mira  shower 

onto existing pipework. 

Note!

 

Some adjustment of pipe 

length may be necessary.

SPARE PARTS

1693.331  

Component Pack (Not illustrated)

1788.436  

Screw Pack (Not illustrated)

1788.424

Mira Jump Cover Assembly

1788.425

Mira Sprint Cover Assembly

1788.439

Outlet 

Connector

1789.085

Latching 

Switch

1788.437

Terminal Block 

Assembly

1788.435

Inlet Filter

1788.434

Solenoid Coil

1788.429

On / Off Switching

Assembly

1746.436

Thermal 

Switch

1788.433

Valve Clamp

N

E

L

MICROSWITCH

(LEFT)

MICROSWITCH

(RIGHT)

BLUE

GREY

BLUE

BROWN

BROWN

BROWN

GREEN

RED

RED

BROWN

BROWN

BLUE

BLUE

GREEN

BLUE

BROWN

BLUE

RED

N

E

L

GREEN

BROWN

BLUE

BLUE

TERMINAL 

BLOCK

TERMINAL 

BLOCK

LED

START / 

STOP

SOLENOID

HEATER

TANK

1788.438

Earth Terminal 

Block Assembly

1788.440

Wire Loom 

and LED

1788.478 (7.5kW)

     

1788.426 (8.5kW)

1788.427 (9.5kW)

1788.428 (10.8kW)

Heater Tank 

Assembly

(includes

 microswitches)

Отзывы: