6

1060688-W2-P

Design Registration:

000373543-0003

Patents:

GB: 

2 341 667, 2 404 000, 2 427 460,2 428 286

Ireland: 82835, 85128, 85163, 85912

Thank you for choosing a Mira shower. To enjoy the full potential of your new shower, 

please take time to read this guide thoroughly, and keep it handy for future reference. 

Products manufactured by Kohler Mira Ltd are designed to be safe, provided that 

they are installed, used and maintained in good working order, in accordance with 

our instructions and recommendations.

Follow all warnings, cautions and instructions contained in this guide, and on, or 

inside the shower. This guide is also available in digital format from our website or 

by contacting customer services.

Domestic

Light Commercial

Heavy Commercial

Healthcare

Product Variant

Model No.

Colour

Mira Escape

9.0 kW

J95Hb/c

Chrome, Satin/Chrome

Mira Escape

9.0 kW

J95Hf

White

Mira Escape

9.8 KW

J95G/H

Chrome, Satin/Chrome

Mira Escape

9.8 KW

J95Gc

White

Introduction

Products Covered

Recommended Usage

Patents and Design Registration

Содержание Mira Escape Thermostatic 9.0 kW J95Hb/c

Страница 1: ...1 1060688 W2 P These instructions must be left with the user Mira Escape Thermostatic 9 0 9 8 kW Installation and User Guide For SPARES ADVICE or REPAIRS please call us free on 0800 001 4040 UK only ...

Страница 2: ...uction concerning use of the appliance in a safe way and understand the hazards involved 2 Children shall not be allowed to play with the shower 3 DO NOT restrict the water flow from the shower outlet temporarily bending the shower hose or blocking the shower head while in use can cause a hot shot of water to be discharged 4 Cleaning and user maintenance shall not be made by children without super...

Страница 3: ...et mode point handset away from body and make sure that the water temperature has stabilised before continuing to shower 16 Use caution when altering the water temperature always check the temperature before continuing to shower 17 Switch the shower off at the electrical isolating switch when not in use This is recommended with all electrical appliances 18 Installation of the shower must be carrie...

Страница 4: ...uld also be drained of water 26 If the shower is dismantled during installation or servicing then upon completion an inspection must be made to ensure all electrical connections are tight and that there are no leaks 27 This appliance is intended to be permanently connected to the water mains and not connected by a hose set 28 The water inlet of this appliance shall not be connected to a water supp...

Страница 5: ...ncluded Documentation 1 x Installation and User Guide 1 x Installation Template 1 x Guarantee and Registration Document Wiring Diagram BROWN BROWN BROWN BLUE BLUE GREEN GREEN BROWN BROWN BROWN BLACK BLACK BLACK RED RED RED Thermal Cutout Dual Disc Tank Connection Load Inlet Connector Pressure Power Selector Switch Solenoid Valve Low Flow Neon Power On Neon START STOP L E N Internal Wiring Diagram ...

Страница 6: ...nd maintained in good working order in accordance with our instructions and recommendations Follow all warnings cautions and instructions contained in this guide and on or inside the shower This guide is also available in digital format from our website or by contacting customer services Domestic Light Commercial Heavy Commercial Healthcare Product Variant Model No Colour Mira Escape 9 0 kW J95Hb ...

Страница 7: ... with 3 mm contact separation Appliance Sealing Rating IP X4 Suitable for installation in Zone 1 MaximumAmbient Temperature 30 C Minimum Ambient Temperature 2 C Plumbing Variant Escape 9 0 Escape 9 8 Minimum Dynamic Pressure 70 kPa 0 7 bar 70 kPa 0 7 bar Maximum Dynamic Pressure 500 kPa 5 bar Maximum Static Pressure 1000 kPa 10 bar Minimum Static Pressure 20 kPa 0 2 bar Maximum Inlet Temperature 3...

Страница 8: ...d of one year from the date of purchase For terms and conditions refer to section Customer Services Guarantee The Mira Escape range of showers comply with the following European directives 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive The Mira Escape range of showers are high power appliances and are subject to conditional connection If the main electrical supply fuse is rated less th...

Страница 9: ...erproof flat and even wall surface 8 DO NOT fit the shower to the wall and tile up to the case 9 DO NOT seal the gap between the shower and the wall surface 10 The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle 11 The showerhead must be directed away from the shower unit during normal use the showerhead must not spra...

Страница 10: ...l installation until the plumbing has been completed and checked for leaks Hose retaining ring fitted and shower fittings fixed at a suitable height preventing dirty water backflow Note There will be occasions when the hose retaining ring will not provide a suitable solution for Fluid Category 3 installations in these instances an outlet double check valve must be fitted this will increase the req...

Страница 11: ... A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provided with means for local disconnection that is incorporated into the fixed wiring in accordance with the relevant local wiring regulations This must be a double pole switch which has at least 3 mm conta...

Страница 12: ...y must be turned off at the mains and the appropriate circuit fuse removed if applicable Note An installation template is supplied to help you install the shower Remove the three cover retaining screws the cover and the service tunnel Cover Cover Retaining Screw Service Tunnel Installation of Mira Escape Wall fixings are not supplied For solid wall structures a red rawl plug and a no 8 x 1 counter...

Страница 13: ...n the wall and mark through the positions of the fixing holes Make sure that the position of these holes do not come in line with any buried cables or pipework Make sure that sufficient electrical supply cable is available for connection to the terminal block Drill and plug the top two fixing holes Secure the Mira Escape to the wall with appropriate screws Drill the bottom fixing hole with the pro...

Страница 14: ...N E GREEN YELLOW N BLUE Refit the Service Tunnel and Cover Make sure they fit correctly Do not overtighten screws Do not use alternative screws to secure the Cover This can cause internal damage to the appliance Do not seal around the back of appliance Cover Cover Retaining Screw Service Tunnel ...

Страница 15: ...15 1060688 W2 P Cold Water Supply Pipe Bottom Entry Service Tunnel Fixing Screw Holes For Cover Retaining Screws Case Insert Electrical Supply Cable Terminal Block Inlet Connector Assembly Heater Tank ...

Страница 16: ...full force and at a cool temperature Turn the control slowly Temperature remains cool and flow is reduced Electrical supply is turned off at the mains COLD 0 5 Secs 1 4 3 2 6 5 9 8 7 Before carrying out the commissioning procedure install the Shower Fittings refer to the Shower Fittings Installation and User Guide If you are unsure how an electric shower works please read through the section User ...

Страница 17: ...ater from its tank for a few seconds Residual water may drain over a few minutes Set control to III 5 10 Secs 0 5 Secs 13 15 14 16 _ Press STOP button light on the button goes out Shower flow will continue for a few seconds before stopping Isolate power 17 18 Note A slight hissing sound may be heard from the Mira Escape during operation High mains water pressure and high shower temperatures will a...

Страница 18: ...ns _ COLD _ _ The warmer the shower the lower the flow rate and vice versa Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has three heater settings How Your Electric Shower Works ...

Страница 19: ...rature across the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this temperature is factory set and cannot be adjusted to make the shower hotter or colder Thermostatic Temperature Stable THERMOSTATIC ELECTRIC SHOWER ORDINARY ELECTRIC SHOWER ...

Страница 20: ...een turned off This may drain over a few minutes Press the Start Stop button light on the button comes on 2 Switch on electrical supply 1 Set to desired position 3 Residual water may drain over a few minutes 7 4 _ Check water temperature before entering shower 5 _ Allow 10 15 seconds for any temperature adjustments to reach the handset 6 Press STOP button light on the button goes out Shower flow w...

Страница 21: ... the required operating parameters refer to section Specifications For a cold shower select I For a summer warm shower select II For a winter warm shower select III During extremes of mains water supply temperature adjust heater setting to obtain a better showering temperature The Effect of Seasonal Changes The Effect of Other Water Devices Example of how shower temperature stabilises due to press...

Страница 22: ...ke sure incoming mains water stopcock and or appliance isolating valve is fully turned on ON OFF II III Temperature dial or Heater setting too high Turn the heater selector knob to setting II or turn the temperature control until a cooler temperature is achieved Thermostatic mechanism is faulty or damaged Replace U n a b l e t o s e l e c t a cool enough shower ON OFF III Due to the rise in mains ...

Страница 23: ...ly pipework or inlet filter restricted by a blockage or partial blockage Flush supply pipe Clean inlet filter I n s u f f i c i e n t w a t e r supply pressure flow for operation Contact local water company Supply pressure must be a minimum of 0 7 bar Note If other appliances are operating pressure may drop below 0 7 bar Other outlets e g toilet garden hose washing machine etc drawing water while ...

Страница 24: ...mpany Check mains water static pressure Appliance fails to produce hot water when set on II III heater settings ON ON II III Insufficient water supply Contact local water company ON OFF Possible failure of the microswitch or thermal switch Contact local water company Heater Tank failure Replace User Maintenance There are no user serviceable parts inside the shower Only qualified competent personne...

Страница 25: ... and printing and should not be used These finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth Unscrew the hose from the showerhead and the shower outlet Inspect the hose De scaling the Showerhead and inspecting the hose Warning Failure to keep the showerhead nozzles clear or inspect the hose for blockage or internal external collapse ...

Страница 26: ...at the electrical supply is turned off at the mains and that the water supply is fully turned off Remove the three screws the cover and the service tunnel Inlet Filter Cleaning Renewing Read the section Important Safety Information first Warning There are no user serviceable parts inside the shower Servicing of the shower must only be carried out by qualified competent personnel following the inst...

Страница 27: ...ssembly A A A 1563 537 Control Belt 1563 694 Neon Assembly 1563 547 Satin 1563 548 Chrome 1563 784 White Service Tunnel and Case Inserts B C D A 416 48 Latching Switch 416 51 Coil 1563 538 Cam and Pulley 1563 540 Inlet Valve 1563 522 Cover Seal not shown 1563 541 Screw Pack identified A 1563 550 Component Pack Satin identified B 1563 551 Component Pack Chrome identified C 1563 787 Component Pack W...

Страница 28: ... Gloucestershire GL52 5EP 14648 Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase This guarantee only applies in the United Kingdom and Republic of Ireland Activating Your Guarantee Registering your guarantee is quick and simple To ensure your product is covered please register online Scan the QR code to activate your guarantee now or cal...