Symptom
Power
Light
Low
Flow
Light
Heater
Setting
I / II / III
Probable Cause
Possible Remedy
(continued)
Unable to
select a
hot enough
shower (cold
only)
ON
ON
Any
Hose kinked or blocked
Check hose and
replace if necessary,
see section
- 'USER
MAINTENANCE'
.
Restriction in
Showerhead mode
Select different
Showerhead mode
H a n d s e t
dripping
OFF
OFF
ANY
Insufficient water supply
pressure for shut off.
The minimum static
pressure to ensure shut
off and prevent dripping
is 0.2 bar.
Note:
If other appliances
are operating, static
pressure may drop below
0.2 bar. Contact local
water company. Renew
the Flow Valve.
Inlet valve faulty
Replace
Low or no flow
ON
ON
ANY
Water supply pipework
or inlet filter restricted
by a blockage or partial
blockage.
Flush supply pipe. Clean
inlet filter.
I n s u f f i c i e n t w a t e r
supply pressure/flow for
operation.
Contact local water
company. Supply pressure
must be a minimum of
0.7 bar.
Note:
If other
appliances are operating,
pressure may drop below
0.7 bar.
Other outlets (e.g. toilet,
garden hose, washing
machine, etc.) drawing
water while the shower is
being used.
Turn off other appliances
whilst shower is in use.
ON
OFF
ANY
Showerhead blocked
Remove and clean.
Service tunnel or cover
not fitted correctly causing
Start/Stop button not to
operate.
Check case inserts are
cut and fitted correctly.
Check services (electrical
or plumbing) are not
interfering with location
of service tunnel or cover.
Inlet Valve faulty.
Replace.
Heater Tank excessively
scaled.
Replace. In hard water
areas consider the use of
a water softener.