13
1060688-W2-P
Three case inserts are supplied with the Mira Escape, so that they can be trimmed
to suit the supplies entering the product. Before fitting the cover, make sure that the
case inserts are fitted.
Thoroughly flush the mains-fed cold water supply pipe. The supply must be
clean and free from debris BEFORE connecting the Mira Escape
.
To flush the pipework, turn on the water supply and drain a minimum of 10 litres
(2 gallons) of water into a bucket or catchment area. Turn off the water supply.
An installation template is supplied to help you install the Mira Escape.
Put the installation template on the wall and mark through the positions of the fixing
holes. Make sure that the position of these holes do not come in line with any buried
cables or pipework. Make sure that sufficient electrical supply cable is available for
connection to the terminal block.
Drill and plug the top two fixing holes. Secure the Mira Escape to the wall with
appropriate screws. Drill the bottom fixing hole with the product in place. Alternative
fixings (not supplied) may be necessary for some wall structures. Avoid drilling into
any supply cable/pipe.
Install the mains-fed cold water supply
pipe. Do not overtighten.
Feed cable into Case. Fit Earth sleeve (not
supplied) and strip insulation.
Do not twist cable cores.
Important!
Make sure
that the inlet earth wire is
routed as shown. Failure
to do so may cause
product malfunction.