Operating fluids and maintenance
Operation and Maintenance Manual
Maintenance schedule — COP Fuel optimized
5.9.2 COP Fuel optimized — Service level 2
SL204 Cylinder head
valves
1000
2
X
Check / set valve clearance.
SL119
-A
Exhaust gas
turbocharger
7500
X
Replace the exhaust gas turbocharger rubber sleeve.
SL225 Viscous damper
10000
X
Replace the viscous damper.
SL205 Injection
10000
X
Replace fuel lines and injectors.
SL213 Exhaust gas
turbocharger
10000
X
Replace the exhaust gas turbocharger.
SL215 Water pump
10000
8
X
Replace the water pump.
SL219
-B
Lines
10000
4
X
X
Check and replace lines and hoses if necessary.
SL223 Battery charging
alternator
10000
X
Replace the battery charging alternator.
SL209 High pressure
pump
20000
X
Replace the HP pump.
Tab. 29: COP Fuel optimized — Service level 2
58
© 2017 by Kohler Co. All rights reserved.
KD27V12 33521029401_3_1 en 2017-07-01