Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Before You Begin
DANGER: Risk of scalding or other severe injury.
Before
completing installation, the installer must set the maximum
water temperature setting of this valve to minimize the risks
associated with scalding hazards according to ASTM F 444.
CAUTION: Risk of scalding.
This device has been calibrated at
the factory to ensure a safe maximum water temperature. Any
variance in settings or water inlet conditions from those used
during factory calibration may raise the discharge temperature
above the safe limit, and may present a scalding hazard.
Responsibility for installation and adjustment of this device in
accordance with these instructions lies with the installer.
Shut off the main water supply.
Observe all local plumbing and building codes.
The valve is calibrated to 104° F (40° C) at the first stop position,
and the maximum temperature limit stop is positioned so the
outlet water temperature does not exceed 120° F (49° C).
Thermometer
Thread
Sealant
Plumbers
Putty
Hex
Wrench
Assorted
Screwdrivers
Kohler Co.
3
1012606-2-B
Содержание K-T9493
Страница 29: ...1012606 2 B...
Страница 30: ...1012606 2 B...
Страница 31: ...1012606 2 B...
Страница 32: ...USA 1 800 4 KOHLER Canada 1 800 964 5590 M xico 001 877 680 1310 kohler com 2004 Kohler Co 1012606 2 B...