1374956-T01-B
-9-
第六步:
安装
C
夹:将台面和柜体用
C
夹套住,用十字螺丝刀锁紧螺母。
第七步:
A.
连接水路:
1.
连接前先排掉角阀内部污水;
2.
将恒温阀热水进口与左边热水角阀对接,用扳手锁紧;
3.
进水管一端和恒温阀冷水进水端对接,另一端与右边冷水角
阀对接,用扳手锁紧;
4.
另一条进水管一端和恒温阀出水口对接,另一端和电磁阀组
件进水口对接,用扳手锁紧。
注:当只有冷水阀时,只需将进水管的一端与冷水阀对接,
另一端与电磁组件进水口对接即可!
B.
水路连接检查:
1.
打开冷热水阀,检查电磁阀前端进水管的接头不得有漏水和
封密不良
;
2.
将电磁阀
1
和
2
的开关旋钮向“常开”方向旋到底,检查后
端出水管对接头不得有漏水和封密不良;
3.
用对边(
8mm
)六角扳手调节稳压阀
1
和
2
让其水花达到要
求水形;
4.
检查排杆处管路不得有漏水和封密不良;
5.
检查全部不漏水后,将电磁阀
1
和
2
的开关旋钮向“感应”
方向旋到底。
Step 6:
Install C clips: Fix the top cover and cabinet with C clips, and
tighten the nuts with a cross screwdriver.
2 M5 Screw
2-M5
夊
Use two C clips to fix the cabinet and top cover,
and tighten them with a cross screwdriver.
ऀ
2
З
C
צ٘୧ব߱ѽЊՖவ
;
ऀԝ夊ВӢ୧ব澞
2-C Clip
2-C
צ
Step 7:
A. Connect waterway:
1. Drain the sewage inside the angle valve pipe before
connection.
2. Connect the hot water inlet of the thermostatic valve with
the hot water angle valve on the left. Tighten them with a
wrench.
3. Connect one end of the hose with the cold water inlet of the
thermostatic valve. Connect another end with the cold water
angle valve on the right. Tighten them with a wrench.
4. Connect one end of the other hose with the outlet of the
thermostatic valve. Connect the other end with the inlet of
the solenoid valve assembly. Tighten them with a wrench.
Note: When there is a cold water valve only, just connect
one end of the hose with the cold water valve, and the other
end with the inlet of the solenoid assembly!
B. Check waterway connection:
1. Open the cold and hot water valves. Check whether or not
the joint of inlet pipe on the front end of the solenoid valve is
leaking or sealing poorly.
2. Rotate the switch knobs of solenoid valve 1 and 2 toward the
"Normal Open" totally. Check whether or not the connector
of the rear outlet pipes is leaking or sealing poorly.
3. Adjust the pressure regulator 1 and 2 with a hex wrench
(8mm) to make the water spray appearance meet the
requirements.
4. Check whether or not the pipeline at the drain assembly is
leaking or sealing poorly.
5. Rotate the switch knobs of solenoid valve 1 and 2 toward the
"Induction" totally after confirming that there is no leakage.