7.
;
;
L
3mm
3.5mm
·
·
·
7. Fix faceplate
Note:
Put the faceplate onto the bottom board.
Pull the faceplate downwards.
Tighten the rod with L wrench.
When removing the faceplate, unscrew the screw 3mm
out and push the faceplate 3.5mm upwards to remove it.
·
·
·
-5-
Faceplate Assembly
Button Assembly
Top Screw
Wrench
Fig.9
9
Lock
Pull
Snap
8.
7
·
·
·
8. Maintenance
Test run and check the valve after installation. Leakage at
inlet connector:
Refer to Fig.7 to check whether the seal is properly
installed, nut is tightened and whether the inlet pipe is at
proper vertical and horizontal level.
Leakage at outlet connector: Check whether the surface is
smooth, the seal is twisted and the nut is tightened.
Water cannot be stopped: Press the rod to check whether
it can be restored, there is wastes inside and valve
assembly is blocked.
·
·
·
1299535-T01-C