1. Install the Vacuum Breaker
CAUTION: Risk of property damage.
Do not subject the
vacuum breaker to continuous pressure for more than twelve
hours.
NOTE:
Install the vacuum breaker at least 6
″
(15.2 cm) above the
fixture rim. Consult local codes for vacuum breaker height.
NOTE:
Apply a thread sealant where applicable.
Thread one 1/2
″
nipple into both the supply outlet piping and
the supply inlet piping. Ensure that the threads of each 1/2
″
nipple extend beyond the finished wall.
Slide the wall bracket over both the 1/2
″
nipples until it is snug
against the finished wall.
Insert one sleeve through each hole of the wall bracket and
thread onto each 1/2
″
nipple. Secure with a seat wrench or a
7/16
″
square bar. Do not overtighten.
Finished
Wall
1-3/8"
(3.5 cm)
1/2" I.P.S.
Nipples
Wall Bracket
Sleeve
O-Ring
Outlet
Port
Socket Head
Screw
Vacuum Breaker
Body
Inlet Port
1034416-2-A