background image

-1- 

 

HYDRO-TOWER

 

200 

 

 

 

  

200 

 

 

INSTALLATION

 

INSTRUCTIONS 

 

 

 

 

IN-WALL

 

TANK 

 

K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNE 
K-20008T-PNE/K-20008K-PNE/K-78073T-PNE/K-78073K-PNE 
K-78074T-PNE/K-78074K-PNE/K-78075T-PNE/K-78075K-PNE 

 

 

 

 

K-20341T-PNE 

 

 

 

 

 



 

Read

 

installation

 

guide

 

in

 

illustration

 

and

 

word

 

file

 

carefully,

 

and

 

install

 

the

 

tank

 

according

 

to

 

instructions

 

in

 

the

 

guide

 

to

 

avoid 

product

 

damage

 

and

 

installation

 

inconvenience

 

caused

 

by

 

inappropriate

 

operation. 

All

 

data

 

contained

 

is

 

based

 

upon

 

the

 

last

 

product

 

information

 

available

 

at

 

the

 

time

 

of

 

publication.

  

Kohler

 

Company

 

reserves 

the

 

right

 

to

 

implement

 

changes

 

of

 

product

 

characteristics,

 

packaging

 

and

 

availability

 

at

 

any

 

time

 

without

 

further

 

notice. 

Do

 

not

 

apply

 

erosive

 

cleanser

 

and

 

solvent

 

in

 

the

 

tank,

 

which

 

will

 

damage

 

tank

 

spares

 

and

 

result

 

in

 

leakage

 

in

 

the

 

tank. 

Kohler

 

will

 

not

 

be

 

responsible

 

for

 

any

 

damage

 

related

 

to

 

above

 

mentioned

 

cleanser

 

or

 

solvent.

 

Mild

 

detergent

 

can

 

be

 

used. 

Do

 

not

 

apply

 

spares

 

that

 

are

 

not

 

provided

 

by

 

Kohler,

 

and

 

please

 

note

 

that

 

glass

 

adhesive

 

tape

 

shall

 

not

 

be

 

applied

 

to

 

the 

installation

 

of

 

Kohler

 

spares.

 

Kohler

 

will

 

not

 

be

 

responsible

 

for

 

any

 

damage

 

related

 

to

 

installation

 

with

 

spares

 

not

 

provided

 

by 

Kohler. 
This

 

product

 

complies

 

with

 

GB26730-2011. 

 

 

 

 

 

 

 

 

 

GB26730-2011 

200 
200 
200 
200 
200 
200 
200 
200 
200 
200 
200 
200 

,2.6/4L

 

......................................................................................................................K-20006T-PNE 

,2.6/4L

 

......................................................................................................................K-20006K-PNE 

,3/4.5L

 

......................................................................................................................K-20007T-PNE 

,3/4.5L

 

......................................................................................................................K-20007K-PNE 

,3/6L

 

.........................................................................................................................K-20008T-PNE 

,3/6L

 

.........................................................................................................................K-20008K-PNE 

,2.6/4L(

                              

)

 

..............................................................................................K-78073T-PNE 

,2.6/4L(

                              

)

 

..............................................................................................K-78073K-PNE 

,3/4.5L(

                              

)

 

..............................................................................................K-78074T-PNE 

,3/4.5L(

                              

)

 

..............................................................................................K-78074K-PNE 

,3/6L(

                              

)..................................................................................................K -78075T-PNE 

,3/6L(

                              

)

 

.................................................................................................K-78075K-PNE 

)(

              

)........................................................................................................................K -20341T-PNE 

Ordering

 

Information 

 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

2.6/4L

  

....................................................................................................................K-20006T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

2.6/4L.....................................................................................................................K -20006K-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

3/4.5L

  

....................................................................................................................K-20007T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

3/4.5L

 

....................................................................................................................K-20007K-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

3/6L

  

.......................................................................................................................K-20008T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

3/6L

 

.......................................................................................................................K-20008K-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

2.6/4L

  

..............................................................................................K-78073T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

2.6/4L...............................................................................................K -78073K-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

3/4.5L

  

..............................................................................................K-78074T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

3/4.5L

  

..............................................................................................K-78074K-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

3/6L

  

.................................................................................................K-78075T-PNE 

HYDRO-TOWER

 

200

 

PNE

 

IWT

 

W/O

 

FRAME

 

3/6L

  

.................................................................................................K-78075K-PNE 

PEBBLE

 

Pneumatic

 

In-Wall

 

Tank

 

Faceplate

  

(For

 

Separate

 

Purchase)...................................................................K-20341T-PNE 

BEFORE

 

YOU

 

BEGIN 

KOHLER

 

CHINA

 

INVESTMENT

 

CO.,

 

LTD

      

NO.158,

 

JIANG

 

CHANG

 

SAN

 

ROAD, 

 

JING'AN

 

DISTRICT,

 

SHANGHAI,

 

PRC

      

POST

 

CODE:

 

200436 

 

 

(

          

)

                                                                                  

158

                      

200436 

©

 

Copyright

 

Kohler

 

China

 

Investment

 

Co.,

 

Ltd.

 

2016 

 

©

                                                                                        

2016 

1288818-T01-A 

Содержание HYDRO-TOWER 200 K-20006K-PNE

Страница 1: ...onsible for any damage related to installation with spares not provided by Kohler This product complies with GB26730 2011 GB26730 2011 200 200 200 200 200 200 200 200 200 200 200 200 2 6 4L K 20006T PNE 2 6 4L K 20006K PNE 3 4 5L K 20007T PNE 3 4 5L K 20007K PNE 3 6L K 20008T PNE 3 6L K 20008K PNE 2 6 4L K 78073T PNE 2 6 4L K 78073K PNE 3 4 5L K 78074T PNE 3 4 5L K 78074K PNE 3 6L K 78075T PNE 3 6...

Страница 2: ...mparative to that of traditional tank Meanwhile the space layout will be more reasonable due to the application of in wall tank pipes and connectors The most remarkable advantage of in wall tank is that the installation will never be limited to certain area and can be installed wherever as you wish which will make the bathroom layout more reasonable and nice looking and make good use of every inch...

Страница 3: ... 3L 4 5L 3L K 20006T PNE K 20006K PNE K 78073T PNE K 78073K PNE Fullflushingvolume 4L Halfflushingvolume 2 6L 4L 2 6L Temperature Environmentaltemperature 1 C 55 C Watertemperature 1 C 45 C 1 C 55 C 1 C 45 C SPECIFICATIONS RECOMMENDES TOOLS AND MATERIALS Open end adjustable wrenches Allen wrench Knife File Hacksaw Masonry Level Screw driver Insulation tape Tape measure Seal tape Bushing Lubricant ...

Страница 4: ...E Installed with K 20341T PNE K 20341T PNE Method three Remote installation of mask Suggested faceplate 85 93 152 3 134 2 477 440 3 3 Method one Press from top Method two Remote plate installation Remote installation of mask Air hose Air hose Air hose Air hose Air hose Pinch plate Pinch plate Pinch plate Suggested faceplate installation area R1000mm Suggested faceplate installation area R1000mm Fi...

Страница 5: ...ipe into the fixing frame then adjust and tighten the knob lock Fill the bottom of the drainage pipe in the drainage hole A B C open lock B C A Discharge Elbow Discharge Elbow Discharge Elbow Water Tank Bracket Water Tank Bracket Water Tank Bracket Drain outlet 90mm welding 90mm Drain outlet 110mm 110mm Drain outlet 110mm welding 110mm Drainage Pipe Tank Bracket Bottom of the Drainage Pipe Drainag...

Страница 6: ...r board inside water tank first as shown Then remove support block and plug above bracket assembly 1 2 Insert the frame screw and screw cap in the holes of fixing frame lock the frame screw with nut then tighten the frame screws on the fixing frame with medium Allen key as shown in illustration A Tighten the bolts with medium Allen key as shown in illustration B and adjust the height of the adjust...

Страница 7: ... bulge screw and tighten the screw 3 10mm 80mm Bulge Screw Gasket Bulge Screw Cap Bolt 4 Tighten the hexagonal long screw with medium Allen key as shown in illustration A Tighten the screw of adjustable brackets with medium Allen key as shown in illustration B and tighten the long screw with spanner NOTE Ensure the tank to remain level 4 A B Hexagonal Screw Loosen Tighten Level Medinm Allen Key Ad...

Страница 8: ...sand stone or fouling inside pipeline 3 1 2 B Floor Discharge Installation Method B 1 There are three methods A B and C for drainage pipe installation Loosen the knob open on the fixing frame put the drainage pipe into the fixing frame then adjust and tighten the knob lock Fill the bottom of the drainage pipe in the drainage hole 1 A B C open lock B C A Discharge Elbow Discharge Elbow Discharge El...

Страница 9: ...k 2 5 Method one Install mask when pressing from top 1 Remove top plate then install the rectangular shield on the top of the tank and tighten the screw to fix the mask to the tank 5 1 Method three Remote installation of mask Suggested faceplate installation area R1000mm Air hose Air hose Method four Press from front Pinch plate Air hose Pinch plate Suggested faceplate installation area R1000mm Me...

Страница 10: ...e air hose Pull it out from the front of the tank and meanwhile reserve the access panel Fix the four plates with screws and then fix the support board Note No direct contact between the faceplate and the tank 7 20mm thickness recommended for the wall of the pinch plate 7 Cover Top Cover Front At least 80mm gap reserved 80mm At least 80mm gap reserved 80mm At least 80mm gap reserved 80mm Air hose ...

Страница 11: ...on of Toilet D 1 Install the inlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pencil and reserve appropriate space according to the distance from the back of the tank to the inlet hole on the wall 1 110mm into C Installation of P trap C 1 Insert drainage pipe with inner diameter drain elbow and weld 1 110mm Water Tank Bracket Drainage Pipe W...

Страница 12: ...pe Drainage Pipe Big Leak proof Gasket 2 Eliminate unwanted part of the inlet pipe according to the marks of reserved space and rasp a smooth surface with files 2 3 Install the big and small leak proof gaskets on inlet pipe and outlet pipe then install it to corresponding pipes on the toilet tank 3 4 48mm 58mm of the long screw shall be reserved outside the wall as shown in the illustration if the...

Страница 13: ...tallation instructions of toilet 6 E Faceplate Installation E 1 When tighten four locknuts on supporting board adjust to OPEN mark as shown 3 Install the big flush air hose and small flush air hose to the cover Put the lock on the cover directly on the reversed lock on supporting board then push the cover and lock it The installation shall begin from bottom to top Note Cut the excessive parts of t...

Страница 14: ...to remain level 2 h 80mm O10mm Bulge Screw Fixing Bracket Gasket Spring Nut Installation For In wall Tank Without Frame 4 It is ready to use when connected to water supply after installation Note Reserve access panel at front or top of the tank in remote installation 4 Half Flush Button Full Flush Button h A Installation of In wall Tank A 1 Remove in wall tank from packing box Remove front cover b...

Страница 15: ... on valve flush water supply pipeline Ensure water is clean no residual sand stone or fouling inside pipeline 5 1 2 6 Access Panel Installation Methods There are four ways to install access panel Method one Press from top Method two Remote plate installation fix four plates with screws Method three Remote installation of mask Method four Press from front fix four plates with screws 6 Connecting Pi...

Страница 16: ...t front or top to ensure removal and installation of cover Method two During remote plate installation 7 20mm thickness is recommended for the wall of the pinch plate and at least 80mm gap is reserved Method three During remote installation of mask 4 holes with diameter of 10mm and depth of 16mm are needed to be reserved at the locating hose Drill 10mm holes through air hose on the side of the mas...

Страница 17: ...cable of the air hose Pull it out from the front of the tank and meanwhile reserve the access panel Fix the four plates with screws and then fix the support board Note No direct contact between the faceplate and the tank 7 20mm thickness recommended for the wall of the pinch plate 9 7 20mm Pinch plate installation Pinch plate Method four Press from front Pinch plate Air hose Pinch plate Finished w...

Страница 18: ...Flush Button 11 When finishing the brickwork eliminate unwanted part of the mask the drainage pipe and the inlet pipe if there is mask 11 Inlet Pipe Drainage Pipe REMOVEANDMAINTENANCEOFTHEOUTLETVALVE 1 Remove the air hoses of the big flush and small flush Then remove the faceplate 1 Finished Installation Illustration Faceplate Faceplate Connect to air hose Mask 1288818 T01 A ...

Страница 19: ...gn with OPEN mark 2 OPEN 4 Open close water supply Rotate valve switch to open close water supply as shown 4 5 Unscrew the nut of the metal weaved hose and push the connector of the inlet valve as shown to remove the inlet valve 5 Close Open Valve Conntector Quick release Metal weaved hose nut Supporting Board Locknut 1288818 T01 A ...

Страница 20: ...cket top by hand and then lift up to unlock the bracket Note Push aside the pivot snaps of the big flush and small flush towards lower left to fix back the bracket Lock the snap 7 8 Hold fastener by hand as shown pull the top of fastener along the direction of arrow Then remove fastener 8 Snap Locked Lever Snap 9 Pull discharge valve along the arrow direction as shown to remove discharge valve 9 O...

Страница 21: ...stment open adjustment switch to open the small hole 2 slight drainage adjustment adjust the height of floating box and the water level of slight drainage will be at the bottom of the floating box B 1 2 A Wash Filtration Net Close corner valve first then loosen and take out the tighten nut and wash the waste on filtration net with clean water Then reset the tighten nut to the original position A T...

Страница 22: ...d squat Thefloatingboxoftheinletvalveisblockedby wastes sothewaterisleakedfromtheoverflow pipe Readjustthepositionofotherpartstoavoid contactingthefloatingboxwhenitis functioning Therubbergasketisblockedbywastes Takeouttheoutletvalveandcleanthe wastes Toiletdoesnotflush A Nowatersupply B Thewatersupplystopisclosed A Waitforrestorationofwatersupply B Openthewatersupplystop Toiletdoesnotflush comple...

Страница 23: ...A B A B 23 1288818 T01 A ...