1 . Determine the installation location per rough-in dimensions.
     Chisel out a slot and install the supply tubing . Turn off the 
     water supply. The depth of the slot is no less than 90mm, 
     see the figure right for rough-in dimension requirement.

NOTE:

Installation location: No strong ultraviolet radiation or 
electromagnetic field nearby.

2 . Put the flush valve into the slot. Then connect the water
     supply and make the outlet aligned with the center of the
    urinal stall. Secure the flush valve with supporting block to
    make it flat and straight. Then connect the inlet pipe .
    According to the dimensions of the urinal stall, the outlet 
    fitting are connected and installed as shown in the
    rough-in. (See “ROUGHING-IN”)

NOTE:

a. Don’t mistake the direction of inlet and outlet.
b. Please clean the inside of water supply pipe before
    connecting to the product.

INSTALLATION

  安装步骤

1.

根据安装尺寸图确定安装位置,凿出槽坑,埋设供水管,

暂不供水。(槽深不小于

90mm

),尺寸参考右图。

安装交流型时,添加右图虚线内槽坑用于安装电工套管。

注意:

安装位置

:

a. 不能靠近强烈紫外线或电磁场。
b. 不能有光源直射或反射进感应窗口。
c. 不能在感应器正对面有易反射的物品(如镜子、
光亮不锈钢板及其他镜面物体)。

Nut

Outlet Connection

Water Supply (Recommended Inner

Diameter Is More Than 25mm)

Battens

垫紧块

出水连接

螺母

供水管(推荐内径大于

25mm

Installation Site

90

安装区

90

90

75

Install bushing

适合安装
电工套管

28

90

Connect control box while

installing AC

安装交流型时接面板上的电控盒

Outer diameter of Bushing 

is No More Than 25mm

电工套管外径≤

25mm

AC Power Unit

交流电源盒

2.

将冲洗阀放入槽坑内,然后连接进水口,出水口对准小

便器中心。用垫紧块将其固定平整、端正,接好进水管道。
出水配管的连接根据小便器的不同选择安装如尺寸图所示。
(参见”尺寸图”)

注意:

a. 

不要将进出水方向弄错。

b. 

将本产品连接上供水管前,建议先冲洗干净供水管。

6

1206437-T01-A

Содержание 8881T-UC01-AF

Страница 1: ...n to proper installation read all operating and safety instructions All information in these instructions is base upon the latest product information available at the time of publication Kohler China...

Страница 2: ...is 0 10MPa no more than 1L 0 18 0 55MPa 1L 0 1MPa 1L 8881T VC01 BN AF 1L DC 8881T VC03 BN AF 1L AC 0 18 0 55MPa 0 5L 0 1MPa 0 5L Water pressure at 0 18 0 55 MPa average flushing is no more than 0 5L W...

Страница 3: ...Body Inlet Connection Anti Rotating Sheet Nut Gasket Screw M4X50 M4X50 Screw M3X8 M3X8 1100691 SP Assy Filter O ring O 1088695 SP Valver Cover O ring O 1056081 SP Solenoid Valve ACL 219G202 SP Pressi...

Страница 4: ...149 320 40 523 83 126 149 320 40 150 83 126 149 K 5016T YER K 5016T YET 320 40 486 83 126 149 150 83 126 149 358 320 40 486 358 83 126 149 K 18645T Y 0 420 40 455 K 4960T ET K 4960T ER 320 40 523 83...

Страница 5: ...A as top inlet use stainless steel hose as rear inlet c To ensure an effective flush performance an urinal with corresponding flush volume is required And the urinal should comply with ASME A112 19 2...

Страница 6: ...he flush valve with supporting block to make it flat and straight Then connect the inlet pipe According to the dimensions of the urinal stall the outlet fitting are connected and installed as shown in...

Страница 7: ...ed to electric control box by connection wire 3 16306T NA a b 220V c Outlet downwards Outlet upwards Connect to sensor Connect AC Power Supply Connect to sensor Connect AC Power Supply A 1 2 AC Connec...

Страница 8: ...f which the nominal section area of conductor is not less than 0 5mm2 is also recommend DC connection line use wire of which the nominal section area is not less than 0 3mm2 It is cut according to act...

Страница 9: ...e around the valve box Lay the tiles 40 Valve Box Tiles Slurry Mold 4 5 While using DC power take out the battery box from the back side of cover Loose the screws of the battery box assy with a screw...

Страница 10: ...shing Control Stick 1 30 8 10 2 If the urinal is used continuously the urinal will flush every 2 minutes automatically The urinal enters into working status after the power is connected for 10 seconds...

Страница 11: ...se the valve turn off the fixed cap with screw driver Take out the valve core filter assy and clean with a brush and reinstall them Turn off the water supply or tighten the adjusting bolt before clean...

Страница 12: ...h a brush Please make following checks before repair Symptoms Probable causes Corrective actions If the trouble remains after above mentioned actions are taken please contact with us via distributor N...

Страница 13: ...sensor directly 7 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or acid alkali water and impure water 8 When AC power unit is connected to 20V AC power s...

Отзывы: