Note:

注意:

a. 

以上尺寸仅供参考。

b. 

出水配件需另行选配。

  

上进水配管选配

K-2464T-NA,

后进水配管请选用不

  

锈钢编织软管。

 

c. 

为保证有效冲洗,需配相应冲量要求的小便斗,小

便斗本身需符合

ASME A112.19.2-2003

要求,不推荐

用虹吸式小便斗。

d.

为了保证您能放心使用感应器,当配后进水小便器

时,建议用户自行选配内径不小于

9mm

的不锈钢编织

软管,其接口尺寸分别如图所示。

e.

为保证有效冲洗,推荐供水管路(包括水表、阀等)

内径不小于

25mm

,推荐供水水压(冲洗器进水口流动

水压):

0.18MPa

0.55MPa

 

a. The dimensions above are just for reference.
b. The connection take between the outlet connection
and urinal is not supplied in this package.
Please use K-2464T-NA as top inlet, use stainless
steel hose as rear inlet
c. To ensure an effective flush performance, an urinal
with corresponding flush volume is required. And
the urinal should comply with ASME A112.19.2-2003.
Siphon urinal is not recommended.
d. To insure you can use the sensor with ease, when
used with rear inlet urinal, recommended inner diameter
of stainless steel hose chose by customer is no less
than 9mm.The connection dimensions are shown in the
figures.
e. TO ensure an effective flush performance strongly
recommended inner diameter of water supply (including
water meter, valve, etc.) is no less than 25mm, and
supplied water pressure(sensor inlet dynamic pressure)
is 0.18Mpa~0.55Mpa.

1206437-T01-A

5

Содержание 8881T-UC01-AF

Страница 1: ...n to proper installation read all operating and safety instructions All information in these instructions is base upon the latest product information available at the time of publication Kohler China...

Страница 2: ...is 0 10MPa no more than 1L 0 18 0 55MPa 1L 0 1MPa 1L 8881T VC01 BN AF 1L DC 8881T VC03 BN AF 1L AC 0 18 0 55MPa 0 5L 0 1MPa 0 5L Water pressure at 0 18 0 55 MPa average flushing is no more than 0 5L W...

Страница 3: ...Body Inlet Connection Anti Rotating Sheet Nut Gasket Screw M4X50 M4X50 Screw M3X8 M3X8 1100691 SP Assy Filter O ring O 1088695 SP Valver Cover O ring O 1056081 SP Solenoid Valve ACL 219G202 SP Pressi...

Страница 4: ...149 320 40 523 83 126 149 320 40 150 83 126 149 K 5016T YER K 5016T YET 320 40 486 83 126 149 150 83 126 149 358 320 40 486 358 83 126 149 K 18645T Y 0 420 40 455 K 4960T ET K 4960T ER 320 40 523 83...

Страница 5: ...A as top inlet use stainless steel hose as rear inlet c To ensure an effective flush performance an urinal with corresponding flush volume is required And the urinal should comply with ASME A112 19 2...

Страница 6: ...he flush valve with supporting block to make it flat and straight Then connect the inlet pipe According to the dimensions of the urinal stall the outlet fitting are connected and installed as shown in...

Страница 7: ...ed to electric control box by connection wire 3 16306T NA a b 220V c Outlet downwards Outlet upwards Connect to sensor Connect AC Power Supply Connect to sensor Connect AC Power Supply A 1 2 AC Connec...

Страница 8: ...f which the nominal section area of conductor is not less than 0 5mm2 is also recommend DC connection line use wire of which the nominal section area is not less than 0 3mm2 It is cut according to act...

Страница 9: ...e around the valve box Lay the tiles 40 Valve Box Tiles Slurry Mold 4 5 While using DC power take out the battery box from the back side of cover Loose the screws of the battery box assy with a screw...

Страница 10: ...shing Control Stick 1 30 8 10 2 If the urinal is used continuously the urinal will flush every 2 minutes automatically The urinal enters into working status after the power is connected for 10 seconds...

Страница 11: ...se the valve turn off the fixed cap with screw driver Take out the valve core filter assy and clean with a brush and reinstall them Turn off the water supply or tighten the adjusting bolt before clean...

Страница 12: ...h a brush Please make following checks before repair Symptoms Probable causes Corrective actions If the trouble remains after above mentioned actions are taken please contact with us via distributor N...

Страница 13: ...sensor directly 7 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or acid alkali water and impure water 8 When AC power unit is connected to 20V AC power s...

Отзывы: