T
TROUBLESHOOTING
No flushing
(Indicator not flashing).
1. No power or mistake connected.
2. There is an object within the sensing distance.
3. The sensing window needs cleaning.
1. Check the power connect.
2. Remove the object.
3. Clean the window.
Keep flushing indicator not
flashing.
Indicating light
keeps flashing and no
flushing.
1. The small hole of diaphragms assembly
is blocked.
2. Foreign objects exist in valve chamber.
1. Clean the small hole of diaphragms
assembly.
2. Clean the valve chamber and diaphragms
with a brush.
Please make following checks before repair:
Symptoms
Probable causes
Corrective actions
If the trouble remains after above-mentioned actions are taken, please contact with us via distributor.
No flushing or poor
flushing while the indicator
can flash.
1. Adjusting bolt not fully open.
2. Low water pressure.
3. Filter is obstructed.
4. The connector is not connected well.
5. The filter of valve core is blocked.
1. Open the adjusting bolt.
2. Improve water supply.
3. Clean the filter.
4. Check the connector.
5. Wash the filter of valve core with a brush.
感应指示灯连续
闪烁而不出水
请在委托修理前做以下检查:
现象
原因
处理方法
不出水
(感应指示灯不亮)
感应指示灯闪烁
而无水流出或出水较差
不停水
1.
电池装反
(
仅用于直流型
)
2.
感应范围内有其他物体一直被感应
3.
感应窗口较脏
4.
无电源或接线有误
1.
调节栓未完全打开
2.
水压太低
3.
过滤装置脏堵
4.
接线端未接好
5.
阀芯滤网脏堵
1.
膜片组件小孔堵塞
2.
阀腔内有杂物
1.
检查电池
(
仅用于直流型
)
2.
清理物体
3.
清洁窗口
4.
检查电源连接
1.
打开调节栓
2.
改善供水情况
3.
清洗过滤装置
4.
检查接线端
5.
清洗阀芯滤网
1.
清理膜片组件小孔
2.
清洗阀腔与膜片
如按以上操作仍然未解除故障,请通过销售商与本公司联系。
1. Out of electricity (DC).
2. Just power cut (AC).
1. Replace batteries.
2. Check the power supply.
1.
电池耗尽
(
直流型
)
2.
刚刚停电(交流型)
1.
更换新电池
(
直流型
)
2.
检查总电源(交流型)
12