USER S GUIDE

Working Status Flushing

Deodorizing Flushing

Flushing Volume

When the water pressure or flush amount exceeds a certain 
limit, take off the cover and turn the adjusting bolt clockwise
with hex pan to a proper place.

Manual Flushing

Normal working status, approach the supplied special magnetic
stick (flushing control stick) to the right part of the sensor lens.
The system is now at a manual status and the indicator will flash
every 1 seconds. Approach the flushing control stick to the right
part of the sensor lens once, it ll flush once. The maximum flush 
time is approximately 30 seconds. This status will last for 
about 8 minutes until turns to the normal working status.

If the flushing control stick keeps near to the

sensing window for 30 seconds, the manual
status will be terminated automatically and
reassume the normal working status.

NOTE:

Adjustment Bolt

调节栓

Flushing Control Stick

,

,

在正常工作模式下,用配备的专用磁棒(冲洗控制棒)靠近
感应窗口右侧位置,此时系统进入手控状态,感应指示灯每

1

秒闪烁一次。用冲洗控制棒每靠近感应窗口右侧一次,小

便器即放水冲洗一次,冲水最长时间约为

30

秒。此状态维持

8

分钟。结束后转为正常工作状态。

当水压过大或冲水量偏大时

,

取下面板

,

使用六角扳手顺时

针方向调节水量调节栓至适量即可改善冲水量

接通电源

10

秒后即可进入工作状态。

当连续有人使用时,小便器每

2

分钟自动冲洗一次。

If the urinal is used continuously, the urinal will flush every 
2 minutes automatically.

The urinal enters into working status after the power is 
connected for 10 seconds.

使用说明

工作状态

防臭冲洗

水流量

手控冲洗

注意:冲洗控制棒如持续超过

30

秒一直不离开感应窗口,

将自动解除手控冲洗状态回复到正常工作状态。

冲洗控制棒

PSD ECO 0.5&1L flush mode change

The default flush mode of sensor is 0.5L , you can switch to 
the 1L flush mode with flushing control stick. Operate as 
follow: after initial power on, during the time of the indicator 
flashing, you can switch the flush mode by putting the flushing 
control stick near the right part of the sensor lens. There will 
be twice quick rinse after you complete the 1L flush mode 
setting. If you need to reset the 0.5L flush mode, you can cut 
off the power completely and restart the sensor, during the 
time of the indicator flashing, you're able to switch flush mode 
with flushing control stick, there will be once quick rinse after 
you complete the 0.5L flush mode setting.

NOTE:

 

just for 8881T-VC01-BN/AF(PSD ECO 0.5&1L /DC)

8881T-VC03-BN/AF(PSD ECO 0.5&1L /AC)

0.5L

1L

可调式冲洗模式切换

:

产品出厂默认设置为

0.5L

冲洗模式,可以使用冲洗控制棒将产品

设置为

1L

冲洗模式。具体操作方法如下:产品初始上电,在指示

灯显示长亮的时间内,用配备的专用磁棒(冲洗控制棒)靠近感
应窗口右侧位置切换冲洗模式。设置

1L

冲洗模式成功后,会有连

2

次快速冲洗。若需切换回

0.5L

冲洗模式,可侧底断电后重新上

电,在指示灯显示长亮的时间内使用磁棒设置,设置

0.5L

冲洗模

式成功后,会有一次快速冲洗。

注:

仅适用于

8881T-VC01-BN/AF(

0.5L&1L

可调式

/

直流型

)

8881T-VC03-BN/AF(

0.5L&1L

可调式

/

交流型

)

10

1206437-T01-A

Содержание 8881T-UC01-AF

Страница 1: ...n to proper installation read all operating and safety instructions All information in these instructions is base upon the latest product information available at the time of publication Kohler China...

Страница 2: ...is 0 10MPa no more than 1L 0 18 0 55MPa 1L 0 1MPa 1L 8881T VC01 BN AF 1L DC 8881T VC03 BN AF 1L AC 0 18 0 55MPa 0 5L 0 1MPa 0 5L Water pressure at 0 18 0 55 MPa average flushing is no more than 0 5L W...

Страница 3: ...Body Inlet Connection Anti Rotating Sheet Nut Gasket Screw M4X50 M4X50 Screw M3X8 M3X8 1100691 SP Assy Filter O ring O 1088695 SP Valver Cover O ring O 1056081 SP Solenoid Valve ACL 219G202 SP Pressi...

Страница 4: ...149 320 40 523 83 126 149 320 40 150 83 126 149 K 5016T YER K 5016T YET 320 40 486 83 126 149 150 83 126 149 358 320 40 486 358 83 126 149 K 18645T Y 0 420 40 455 K 4960T ET K 4960T ER 320 40 523 83...

Страница 5: ...A as top inlet use stainless steel hose as rear inlet c To ensure an effective flush performance an urinal with corresponding flush volume is required And the urinal should comply with ASME A112 19 2...

Страница 6: ...he flush valve with supporting block to make it flat and straight Then connect the inlet pipe According to the dimensions of the urinal stall the outlet fitting are connected and installed as shown in...

Страница 7: ...ed to electric control box by connection wire 3 16306T NA a b 220V c Outlet downwards Outlet upwards Connect to sensor Connect AC Power Supply Connect to sensor Connect AC Power Supply A 1 2 AC Connec...

Страница 8: ...f which the nominal section area of conductor is not less than 0 5mm2 is also recommend DC connection line use wire of which the nominal section area is not less than 0 3mm2 It is cut according to act...

Страница 9: ...e around the valve box Lay the tiles 40 Valve Box Tiles Slurry Mold 4 5 While using DC power take out the battery box from the back side of cover Loose the screws of the battery box assy with a screw...

Страница 10: ...shing Control Stick 1 30 8 10 2 If the urinal is used continuously the urinal will flush every 2 minutes automatically The urinal enters into working status after the power is connected for 10 seconds...

Страница 11: ...se the valve turn off the fixed cap with screw driver Take out the valve core filter assy and clean with a brush and reinstall them Turn off the water supply or tighten the adjusting bolt before clean...

Страница 12: ...h a brush Please make following checks before repair Symptoms Probable causes Corrective actions If the trouble remains after above mentioned actions are taken please contact with us via distributor N...

Страница 13: ...sensor directly 7 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or acid alkali water and impure water 8 When AC power unit is connected to 20V AC power s...

Отзывы: