Troubleshooting
CAUTION: Risk of product damage. This product contains sensitive electronic
components. Use care not to damage pins and connectors during troubleshooting.
CAUTION: Risk of product damage. Do not insert anything other than the sensor
wire into the sensor wire connector (phone jack) on the circuit board.
NOTE: For service parts information, visit your product page at www.kohler.com.
Faucet Troubleshooting Table
Symptoms
Probable Causes
Recommended Action
1. No water
fl
ow.
A. The supply stops
are closed.
A. Con
fi
rm the supply stops are open.
B. Handle is in the
closed position.
B. Rotate the handle to the open position.
Refer to the
″
Faucet Operation
″
section.
C. The hot and/or
cold supply hose
is kinked.
C. Con
fi
rm the supply hoses are not
kinked. If coiled, maintain an inside
diameter of 3
″
(76 mm).
D. The outlet hose
is kinked.
D. Con
fi
rm the solenoid valve is located
within 7
″
(178 mm) to 8
″
(203 mm)
from the faucet base.
E. Handle LED is
not lit.
E. Refer to the
″
Handle Switch
Troubleshooting Table.
″
F. Sensor LED is
not lit.
F. Refer to the
″
Sensor Troubleshooting
Table.
″
G. One or more
screens are
clogged.
G. Refer to the
″
Cleaning the Screens
″
section.
2. Low water
fl
ow.
A. The supply stops
are partially
closed.
A. Con
fi
rm the supply stops are fully
open.
B. Handle is
partially closed.
B. Rotate the handle to the full open
position.
C. The hot and/or
cold supply hose
is kinked or twisted.
C. Con
fi
rm the supply hoses are not
kinked or twisted.. If coiled, maintain
an inside diameter of 3
″
(76 mm).
D. The outlet hose
is kinked.
D. Con
fi
rm the solenoid valve is located
within 7
″
(178 mm) to 8
″
(203 mm)
from the faucet base.
E. One or more
screens are
clogged.
E. Refer to the
″
Cleaning the Screens
″
section.
F. Cracked
diaphragm.
F. Replace the solenoid valve assembly.
3. Poor spray
pattern.
A. The spray
nozzles are
clogged.
A. Rub your
fi
nger over the nozzles with
water running to dislodge debris.
4. Circuit board
LED is not lit.
A. No power to the
circuit board.
A. Check the power supply connections to
the circuit board.
B. Power cord is
plugged into a
switched outlet.
B. Plug the power cord into an
unswitched 220 VAC outlet (test the
outlet with a radio or other device).
Con
fi
rm the circuit board LED
illuminates.
Kohler Co.
19
1198298-2-C
Содержание 72218T-B7-CP
Страница 1: ...Installation and Care Guide Response Electronic Kitchen Faucet 2013 Kohler Co 72218T B7 CP 1198298 2 C...
Страница 4: ...1198298 2 C 4 Kohler Co...
Страница 7: ...3 78 mm 1 Kohler Co 7 1198298 2 C...
Страница 9: ...7 178mm 8 203mm 7 178mm 8 203mm 220VAC LED Kohler Co 9 1198298 2 C...
Страница 12: ...LED LED LED LED LED LED LED LED LED 4 1198298 2 C 12 Kohler Co...
Страница 15: ...Kohler Co 15 1198298 2 C...
Страница 18: ...18 E 4 201206 86 800 820 2628 400 820 2628 1198298 2 C 18 Kohler Co...
Страница 24: ...B B C C 3 LED A A B B 1198298 2 C 24 Kohler Co...