7
.
EtherNet/IP Connection Procedure
38
7.5. EtherNet/IP Communication Status Check
Confirm that the EtherNet/IP tag data links perform normally.
7.5.1. Checking the Connection Status
Check the connection status of the EtherNet/IP network.
1
Check with LED indicators on
Controller that the tag data links
perform normally.
The LED indicators in normal
status are as follows:
NET RUN: Green lit
NET ERR: Not lit
LINK/ACT: Yellow flashing
(Flashing while packets are
being sent and received.)
*The NX-series Controllers also
have the same LED indicator
status.
2
Check the LED indicators on
Manifold Solenoid Valve.
The LED indicators in normal
status are as follows:
Sys.Run Sys.Rdy: Green lit
MS: Green lit
NS: Green lit
L/A OUT: Not lit
L/A IN: Green lit
3
The normal performance of tag
data links can be confirmed
through the status information in
the Monitor Device Dialog Box
of Network Configurator.
Right-click the device icon of
Controller (Node 1) in the
Network Configuration Pane and
select
Monitor
.
Содержание F Series