background image

Symbol

Inner Construction, Major Parts and Materials

 Check  valves  in  which  media  flows  in  one  direction.  
These valves restrict flow in the other direction.

 Mounting  is  simple  due  to  the  integrated  quick  fittings.  
They are perfect for compact piping.

  Excellent durability and the electroless nickel plating fits 

standard specifications.

Minimum operating differential pressure

Recommended tube

0.01 MPa [1 psi] or less

Nylon tube, urethane tube

Sales unit

1 pc.

Operating temperature range

-0.1

0.9MPa [-15

131 psi]

Operating pressure range

0

60

 [32

140

]

Minimum non-return differential pressure

0.02 MPa [3 psi]

Air

Media

Specifications

KCF2651Z

Body configuration and control direction (only to CVS and CVR)

Elastic sleeve (NBR)

Sealant coated

Tube

Release ring (polyacetal)

Lock claw (stainless steel)

Tube end

Valve body (aluminum)

Spring pin (stainless steel)

Metal body (brass

 Note

, electroless nickel plated)

Guide ring (brass, electroless nickel plated)

O-ring (NBR)

KCB2661Z

Free flow direction A
Connecting thread side

Free flow direction A
Male thread side

Free flow

CVS

Release 
ring side

Free flow direction B
Connecting thread side

Release 
ring side

Free flow

Free flow

CVR

Female thread side

Free flow direction B
Male thread side

Female thread side

Free flow

CHECK VALVES

03̲2016

Содержание CVR01 Series

Страница 1: ... 60 32 140 Minimum non return differential pressure 0 02 MPa 3 psi Air Media Specifications KCF2651Z Body configuration and control direction only to CVS and CVR Elastic sleeve NBR Sealant coated Tube Release ring polyacetal Lock claw stainless steel Tube end Valve body aluminum Spring pin stainless steel Metal body brass Note electroless nickel plated Guide ring brass electroless nickel plated O ...

Страница 2: ... Release ring side Free flow Free flow CVR Female thread side Free flow direction A Male thread side Female thread side Free flow Male thread ー Female thread CVR 1 8 01 02 03 04 1 4 3 8 1 2 Thread size R Rc Model sample CVR02A Metal body 1 8 1 4 3 8 1 2 Brass nickel plated Aluminum Thread size Material Name Model R Rc A1 A2 B LNote 1 Width across flats H Effective area mm2 Mass g CVR01 R1 8 Rc1 8 ...

Страница 3: ...e fittings are assembled 2 Put A in the for the model number for input from the male thread side Put B in for output from the male thread side Male thread Female thread CVR R L B A1 A2 H Rc Shape and control direction KCB2661Z Free flow direction A Connecting thread side Free flow direction B Male thread side Free flow CVS Release ring side Free flow direction B Connecting thread side Release ring...

Страница 4: ...bes Confirm that the cut surface of the tube is cut straight across that the outer surface of the tube is not damaged and that the tube has not become oval shaped When connecting tubes if you do not insert the tube all the way to the tube end it may result in leaks After installing the tube pull on it to check that it does not come off Do not meaninglessly press on the release ring before attachin...

Страница 5: ...tic system φ4 0 157 φ6 0 236 φ8 0 315 φ10 0 394 φ12 0 472 Tube size Minimum bending radius Nylon tube Urethane tube 20 0 787 10 0 394 30 1 181 15 0 591 50 1 969 20 0 787 80 3 150 27 1 063 150 5 9 35 1 378 mm in NOTE 1 Use tubing with an exterior that is not damaged If tubing becomes damaged after repeated use cut off the damaged portion 2 Do not allow tubing to become severely bent or twisted near...

Отзывы: