background image

- Page 4 - 

USER MANUAL 

 

 
 
 

NOTICE 

 
 
 
Only the operators that have the knowledge of the method or are able to establish internal 
procedures are authorized to use the apparatus. 
 
 

The qualified operators are however not allowed to work on the device to: 

 

Perform reparations 

 

Modify the components 

 

Use the apparatus for different uses from those imposed by the norm ASTM 

 
For extraordinary maintenance operations (replacement of components, modifications of the system, 
replacement of cables, etc.) it is essential to contact the manufacturer. 
 
Whoever  intervenes  with  the  device  will  act  under  his  own  responsibility  and  cause  the  immediate 
suspension of the warranty. 
 
Before proceeding with a maintenance service, remove the plug from the socket. 
 
The  manufacturer  declines  every  kind  of  responsibility  for  all  the  operations  not  in  conformity  to  the 
aforesaid dispositions or performed by personal without qualification. 
 
The operations of demolition must be entrusted to skilled staff. 
 
The structure and the various components, if unusable, must be demolished and divided according to 
their typology and sent to the center of harvest for the disposal and the recycling. 

 

Содержание K4831X

Страница 1: ...re Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumentation Custom Design Manufacturing K4831X Total Sediment Tester ...

Страница 2: ... Page 2 ...

Страница 3: ... Page 3 USER MANUAL CONTENTS Notice Guarantee Safety information and suggestions Technical specifications of the device Accessories Spare parts Procedure Guarantee certificate ...

Страница 4: ...es etc it is essential to contact the manufacturer Whoever intervenes with the device will act under his own responsibility and cause the immediate suspension of the warranty Before proceeding with a maintenance service remove the plug from the socket The manufacturer declines every kind of responsibility for all the operations not in conformity to the aforesaid dispositions or performed by person...

Страница 5: ...if any The manufacturer is not responsible for the possible damages caused to the device due to wrong connections to the power supply if any In case of extraordinary maintenance personally realised by the customer during the warranty period the guarantee will immediately be suspended The manufacturer reserves himself the right to bring in any moment and without warning changes and innovations resp...

Страница 6: ...NS BELOW 1 Avoid to lean on the apparatus any kind of material 2 Oversee the operating zone in order to avoid the approaching of operators without qualification 3 Always wear suitable clothes 4 Always use masks protective glasses and gloves in conformity to the normative in force 5 Avoid to send water spout on the device 6 Always pay attention when using the apparatus 7 It is severely forbidden to...

Страница 7: ... the end of life is organized and managed by the manufacturer The user that intends to trash this equipment will have to contact the manufacturer and follow the procedure that it has taken to allow separate collection of the apparatus arrived at the end of life Appropriate differentiated collection for the dismantled appliance being subsequently sent out for recycling treatment and for environment...

Страница 8: ...rom 0 to 50 C Storage temperature from 10 to 70 C Ambient relative humidity lower than 90 HR not condensing ACCESSORIES K48319 10 Steam Generator K48319 11 Vacuum Pump K48319 14 GFA filter pack of 100 pcs K48319 9 Thermometer 95 C 105 C SPARE PARTS K48319 14 GFA filter pack of 100 pcs K48319 12 Sintered disc pack of 2 pcs ...

Страница 9: ...media for 20 min in the oven at 110 C Transfer each paper separately rapidly to a numbered weighing bottle and allow to cool in the cooling vessel to room temperature 5 to 10 min Where two pan balances are used weigh each weighing bottle plus filter medium by the tare method against an empty similar bottle to the nearest 0 001 g NOTE 1 Caution The Whatman GF A filter media are fragile and are to b...

Страница 10: ...o an absolute pressure of 40 2 kPa minimum 61 3 kPa vacuum Heat the contents of the beaker to 100 2 C Then transfer the contents at 100 2 C Note 3 to the center of the filter medium taking care that no sample touches the walls during transfer Note 4 Reweigh the beaker to the nearest 0 01 g The quantity transferred should be 10 0 5 g When filtration is not complete in 25 min discontinue the test an...

Страница 11: ...sed before the first solvent washing to ensure complete coverage of the filter medium area by solvent The vacuum should then be gently reapplied for the subsequent operations 6 Apparatus Disassembly 6 1 After the filter medium appears dry discontinue the vacuum supply Using the forceps carefully remove each filter medium separately and transfer them to the oven at 110 C Dry for 20 min and quickly ...

Страница 12: ...filtration is not complete within the specified 25 min report the results as filtration time exceeds 25 min 8 2 Test Report The test report shall contain at least the following information 8 2 1 The type and identification of the product tested 8 2 2 A reference to this test method 8 2 3 The result of the test see 8 8 2 4 Any deviation by agreement or otherwise from the standard procedures specifi...

Отзывы: