16-

 

8  Service

 

 

Under  normal  operating  conditions  and  with 

routine 

maintenance, 

the 

K2269X 

Low 

Temperature  Pressure  Viscometer  should  not 
require  service.  Any  service  problem  can  be 
quickly resolved by contacting Koehler’s technical 
service department either by letter, phone, fax, or 
email.  In  order  to  assure  the  fastest  possible 
service,  please  provide  us  with  the  following 
information. 

 

Model Number:   

 

 

 

 

Serial Number:   

 

 

 

 

Date of Shipment:   

 

 

 

   

        

9  Storage

 

 

This  laboratory  test  instrument  is  equipped  with 

electrical components. Storage facilities should be 
consistent  with  an  indoor  laboratory  environment. 
This testing equipment should not be subjected to 
extremes of temperature and/or moisture. 
 

This equipment was shipped from the factory in 

a  corrugated  cardboard  container.  If  long  term 
storage is anticipated, re-packing the instrument in 
a  water-resistant  container  is  recommended  to 
ensure equipment safety and longevity. 

 

10  Warranty

 

 

We, at Koehler, would like to thank you for your 

equipment  purchase,  which  is  protected  by  the 
following  warranty.  If  within  one  (1)  year  from  the 
date  of  receipt,  but  no  longer  than  fifteen  (15) 
months  from  the  date  of  shipment,  Koehler 
equipment  fails  to  perform  properly  because  of 
defects  in  materials  or  workmanship,  Koehler 
Instrument Company, Inc. will repair or, at its sole 
discretion,  replace  the  equipment  without  charge 
F.O.B. its plant, provided the equipment has been 
properly  installed,  operated,  and  maintained. 
Koehler  Instrument  Company  must  be  advised  in 
writing of the malfunction and authorize the return 

of  the  product  to  the  factory.  The  sole 
responsibility of Koehler Instrument Company and 
the  purchaser’s  exclusive  remedy  for  any  claim 
arising  out  of  the  purchase  of  any  product  is  the 
repair  or  replacement  of  the  product.  In  no  event 
shall  the  cost  of  the  purchaser’s  remedy  exceed 
the  purchase  price,  nor  shall  Koehler  Instrument 
Company  be  liable  for  any  special,  indirect, 
incidental,  consequential,  or  exemplary  damages. 
KOEHLER 

INSTRUMENT 

COMPANY, 

INC. 

DISCLAIMS 

ALL 

OTHER 

WARRANTIES, 

EXPRESSED  OR  IMPLIED,  INCLUDING  ANY 
IMPLIED  WARRANTIES  OF  FITNESS  FOR  A 
PARTICULAR  PURPOSE.  Please  save  the 
shipping carton in the event the equipment needs 
to be returned to the factory for warranty repair. If 
the  carton  is  discarded,  it  will  be  the  purchaser’s 
responsibility  to  provide  an  appropriate  shipping 
carton. 

 

11  Returned Goods Policy

 

 

To  return  products  for  credit  or  replacement, 

please  contact  Koehler  Customer  Service  with 
your  purchase  order  number,  our  packing 
list/invoice number, the item(s) to be returned and 
the  reason  for  the  return.  You  will  be  issued  a 
Returned  Authorization  (RA)  number,  which  must 
be  prominently  displayed  on  the  shipping 
container  when  you  return  the  material  to  our 
plant.  Shipping  containers  without  an  RA  number 
prominently  displayed  with  be  returned  to  the 
sender.  Goods  must  be  returned  freight  prepaid. 
Returns will be subject to a restocking charge, the 
application  of  which  will  depend  upon  the 
circumstances  necessitating  the  return.  Some 
returns  cannot  be  authorized,  including  certain 
products  purchased  from  outside  vendors  for  the 
convenience 

of 

the 

customer, 

products 

manufactured  on  special  order,  products  shipped 
from  the  factory  past  ninety  (90)  days,  and 
products  which  have  been  used  or  modified  in 
such  a  way  that  they  cannot  be  returned  to  stock 
for future sale. 

Содержание K2269X

Страница 1: ...enue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis...

Страница 2: ......

Страница 3: ...tured in conformance with the applicable standards set forth in this certification Specifications ASTM D1092 This unit is tested before it leaves the factory to ensure total functionality and complian...

Страница 4: ......

Страница 5: ...tion 5 4 1 Instrument Descriptions 5 4 2 Top Assembly Description 5 4 3 Control Box Descriptions 6 4 4 Gear Box and Motor Descriptions 7 4 5 Temperature Controller Descriptions 7 5 Operation 9 5 1 Ref...

Страница 6: ...pport of your laboratory testing needs Our products are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument servi...

Страница 7: ...t may exhibit potential hazards Any user must be familiarized with the possible dangers before use We also recommend consulting the Material Data and Safety Sheet MSDS on each chemical reagent for add...

Страница 8: ...e unit and all accessories for damage If any damage is found keep all packing materials and immediately report the damage to the carrier We will assist you with your claim if requested When submitting...

Страница 9: ...ar pump gears drive motor required to power the hydraulic system Refer to section 4 4 for detailed descriptions on this section of the apparatus 4 2 Top Assembly Description Figure 3 Instrument Descri...

Страница 10: ...nect the grease cylinder to the hydraulic system This port is also used as the main connection point for the hydraulic system calibration by utilizing the Calibration Pipe Assembly See Figure 1 Item G...

Страница 11: ...n See Figure 4 item 13 Variable Speed Motor is coupled to the speed reducer and is capable of operating at two speeds required to simulate flow rates attained by 40 tooth gear and 64 tooth gear as per...

Страница 12: ...a certified calibrated measuring device to acquire the temperature Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two t...

Страница 13: ...ion instructions for the temperature controller NOTE Allow for the test chamber to cool and come to temperature equilibrium prior to turning on Drive Motor Recirculating Pump See Figure 4 Item 13 It m...

Страница 14: ...imed 11 Once a steady flow or constant drip rate is observed the hydraulic system is primed and free of air bubbles 12 Using the relief valve at the right hand side of the calibration piping assembly...

Страница 15: ...esting purposes If not attached ferrule will be in thermocouple packaging 3 Remove bottom cap from Grease Cylinder F 4 Invert grease cylinder and place Grease Cylinder Piston C inside Grease Cylinder...

Страница 16: ...cylinder loading procedure is now complete Before attaching a capillary changing the flow of the hydraulic fluid and starting a test the sample grease must attain temperature equilibrium with the test...

Страница 17: ...may result in personal injury or death If you have any questions about maintaining your equipment then please do not hesitate to contact the Koehler technical service department 6 1 Routine Maintenan...

Страница 18: ...104 002 Fuse 25A Slo Blo 5X20 M M 220 240 013 Cartridge Heater 500W 240V 265 500 001 RTD Temperature Probe x 12 275 103 044 Temperature Controller 100 240V 288 230 018 Motor 208 230V 3 Phase 288 230 0...

Страница 19: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 15 7 Wiring Diagrams 7 1 220 240V 50Hz Unit Wiring K22695...

Страница 20: ...e the return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the re...

Страница 21: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 17 Notes...

Страница 22: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 18 Notes...

Отзывы: