Chapter 6 Maintenance
MDC-7000/7900 Series
6-4
0092669002-07
6.3 Method of exchanging the magnetron
6.3.1 Magnetron replacement (RB808 and RB807)
1) Remove the eight screws that secure the shield cover.
Remove the shield cover from the PCB [E61-110X] or [E71-110X].
2) This picture is the view of the magnetron [MAF1565N] or [MAF1562R]
and the pulse transformer [KCT-373]
.
Magnetron MAF1565N
or MAF1562R
Pulse transformer KCT-373
Remove eight screws.