GTD-110/150
Chapter 4
Installation
93151542-00
4-5
4.6.2 Flush mounting
(1) Cut a rectangle opening that measures 190 mm x 194 mm.
(2) Loosen the two (2) fixing knobs that fasten the display unit onto the fixing bracket.
(3) Remove the four (4) plastic screw covers, which are fitted on each corner of the display front face.
(4) Put the display on the opening and fix with four (4) tapping screws. In case you use M4 screws to
fix the display, select an appropriate screw length that best suits fixing the unit to the panel
thickness.
(5) Refit the coverings removed in step (3).
Figure 4.6 Fitting GTD-110 in flush mounting mode
Opening for installation: 300 x 306
Display Unit
Fixing screws
(M4 screws, 4 pcs)
Screw covers (4 pcs)
Before installing the unit,
remove a washer and a knurled
fixing bolt attached on both
sides of the display.
Figure 4.7 Dimensions of opening and fixing holes for GTD-110
308 (12 1/8)
274 (10 13/16)
308 (1
2 1/8)
268
Fixing holes for M4 screw (4 pcs)
16 (5/8)
16 (5/8)
300 (1
1 13/1
6
)
16 (5/8)
16 (5/8)
Unit in mm (inch)
306 (12 1/16)
(10 9/16
)