CVS-875D/877D
Chapter 1 Installation
0092607072-01
1-1
Chapter 1 Installation
1.1 Installation precautions
In order to obtain the maximum performance of the echo sounder, this echo sounder should
be installed by a qualified engineer in charge of installation and maintenance. Installation
procedures include the following:
(1) Unpacking of components.
(2) Inspection of composition units, spare parts, accessories and installation materials.
(3) Checking of supply voltage and current capacity.
(4) Selection of location for installation.
(5) Installation of Display unit, Processor unit, Operation unit and transducer.
(6) Attachment of accessories.
(7) Planning and implementation of cable laying and connection.
(8) Coordination after installation.
1.1.1 Unpacking of components
Unpack components and check that all the items correspond with the description of the
packing list. When a discrepancy or damage has been found, contact the dealer you
purchased or our sales company.
1.1.2 Appearance verification of each unit and accessories
Inspect the appearance of each components and accessories and check that no dents or
damages exist.
If any dents or damages exist and they are believed to be caused by accident during
transportation, contact the transportation and insurance company and consult our sales
company or our dealer nearest to you.
1.1.3 Selection of location for installation
In order to obtain the maximum performance of the unit, it is necessary to install in
consideration of matters described below.
CVS-875D
(1) Install the equipment at a location in a bridge so that its display can be easily seen.
(2) Keep enough space for maintenance. Especially, secure enough space at the rear panel
where many cables are connected.
(3) The Operation unit shall be set up within the distance the connection cables are not too
stretched from the Display unit.
(4) Keep the equipment as far away from wireless transmitter/receivers as possible.
CVS-877D
(1) The Processor unit is not waterproof. Do not set it up in the place where water splashes.
(2) The external monitor shall be set up within the distance the connection cables are not too
stretched from the Processor unit.
(3) The Operation unit shall be set up within the distance connection cables are not too
stretched from the Processor unit.
(4) Keep the equipment as far away from wireless transmitter/receivers as possible.
Содержание CVS-875D
Страница 1: ......
Страница 2: ......
Страница 18: ...Dimensions CVS 875D 877D xvi 0092607072 01 Dimensions CVS 875D Unit mm inch ...
Страница 19: ...CVS 875D 877D Dimensions 0092607072 01 xvii CVS 877D Unit mm inch ...
Страница 20: ...Dimensions CVS 875D 877D xviii 0092607072 01 Operation unit of CVS 875D 877D Unit mm inch ...
Страница 108: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 122: ......