4
■Door camera Installation
Sun Visor (Option)
■ Monitor Installation
■ Directly connecting cut-off power cord with power wire
1) Do not do such electric work on your own. Installing product in this way
requires reliance on electric installation man with electric work license.
2) Insulate with insulating tape while cutting off power cord and connecting with power
wire so electric wire metal does not expose. Contact between exposed electric wires
cause fire or electric shock accident.
3) Such electric work requires connection after interception of supplied power.
1) Remove wall hanger frame metal behind monitor.
2) Install wall hanger frame metal on 1 type box or wall with attached Vis.
3) Connect wiring to monitor back terminal referring to product connection diagram.
4) Hang monitor on metal wall hanger frame and fix monitor on metal wall hanger frame
5) Plug monitor`s power plug into consent and check to see if the power switch is [ON]
on the left side of monitor.
1) Install metal wall hanger frame on type 1 box or on the wall with attached screws.
2) Connect wiring to terminal on the back of door camera referring to product connection diagram.
3) Hang door camera on metal wall hanger frame and fix door camera on metal wall hanger frame
using attached screw.
Avoid heavy rain directed to the product which can cause damage since it is not waterproof.
■ Monitor installation location
·Standard monitor installation height
is about 1,500mm where screen
center is at eye level.
In this case, wall-hanging metal
center (center of piping) is 1,450mm
above ground level.
·Standard installation height
■ Caution of camera Installation
·Avoid installing camera exposed to direct ray of light (and sun).
·Beware backlight and darkness of visitor’s face, which makes identification difficult.
·Avoid installing camera in places such as the following picture.
(1) Place illuminating sky as background
(2) Place with white wall reflecting direct ray of light
(3) Place with direct ray of light
·Standard installation in height
■ Camera installation location
·Camera installation in height Standard
camera installation height is when
lens is about 1,400mm above the floor.
In this case, camera stack center
(piping box) is above 1,390mm above
ground level.
·Standard installation in height
Installation location
Содержание KCV-S701IP2W
Страница 18: ...18 Memo...
Страница 19: ...19 Memo...