Kobold VKA-*102 series Скачать руководство пользователя страница 1

KOBOLD VKA FLOWMETER/SWITCH

User Instructions

      Manual-VKA_03-04

Содержание VKA-*102 series

Страница 1: ...KOBOLD VKA FLOWMETER SWITCH User Instructions Manual VKA_03 04...

Страница 2: ...g Flow 6 4 3 Adjusting the Set point for Decreasing Flow 6 4 4 Contact Protection 7 5 0 Arrival of Damaged Equipment 7 6 0 Need help with your VKA 7 List Of Diagrams Diagram 2 3 Dimensions 3 Diagram 2...

Страница 3: ...compensation Ordinary float type flow meters experience measurement errors of up to 1000 with this type of a viscosity change in the medium At a glance the special features of the VKA are Viscosity c...

Страница 4: ...rational Limits Viscosity Range v 30 300 cSt mm s Maximum Medium Temperature 212 F Maximum Internal Pressure 3600 PSIG Material Brass Housing Spring Orifice Magnet Connections Float Seal Nickel plated...

Страница 5: ...VKA 102 VKA 104 VKA 106 VKA 108 VKA 110 VKA 112 VKA 114 VKA 116 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5...

Страница 6: ...O Contact SPDT Contact Table 2 5 Electrical Data and Operational Limits Maximum Voltage 240 VAC Maximum Current N O 1 5 A SPDT 0 8 A Maximum Power Dissipation N O 50 VA SPDT 30 VA Environmental Protec...

Страница 7: ...eaches the contact reeds of the reed switch the contact actuates As the flow increases the float rises until it reaches its stop This prevents the float from going beyond the contact range of the magn...

Страница 8: ...s on the reed contact housing 2 Slide the contact upwards along its rail until it reaches its stops 3 Open the medium feed line and set flow to desired volume 4 Slide the reed contact downwards until...

Страница 9: ...xceeded on the reed switch When driving inductive or capacitive loads we recommend protecting the contact as dia grammed below If continuous load values exceed contact rating we recommend the use of a...

Страница 10: ...it we advise that you carefully inspect the packing in which it was delivered If damage is visible notify your local carrier at once since the carrier is liable for a replacement under these circumsta...

Страница 11: ...ution PLEASE READ THE FOLLOWING GENERAL FLOW METER MONITOR WARNINGS BEFORE ATTEMPTING INSTALLATION OF YOUR NEW DEVICE FAILURE TO HEED THE INFORMATION HEREIN MAY RESULT IN EQUIPMENT FAILURE AND POSSIBL...

Страница 12: ...using other media especially corrosive ones it is critically important that the user determine chemical compatibility with our instruments A list detailing material composition of our instruments is...

Страница 13: ...can be substantial not to mention the car The water hammer causes surges in fluid pressure which could cause the measurement instrument s pressure limit to be exceeded resulting in failure and possibl...

Отзывы: