Kobold SMO Series Скачать руководство пользователя страница 1

 

 

 

Operating Instruction 

for 

Flow Meter / Monitor 

 

Model: SMO-... 

             SMW-... 

 

Содержание SMO Series

Страница 1: ...Operating Instruction for Flow Meter Monitor Model SMO SMW...

Страница 2: ...SMW 2 6 7 2 Examples for Contact Protection Measures 6 8 Commissioning 7 9 Maintenance 8 10 Technical Information 9 11 Order Codes 10 12 Dimensions 12 13 Recommended Parts 13 14 EU Declaration of Con...

Страница 3: ...st in paper form against an applicable postage fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulation...

Страница 4: ...provided as follows Flow measurement The actual flow may be read locally off the instrument indication which is mounted at the side of the housing The scale shows the flow rate directly in litres per...

Страница 5: ...allowable maximum operating pressure and operating temperature of the instruments are not exceeded The instrument should be installed in a vertical model SMO or horizontal model SMW position in the pi...

Страница 6: ...g Push the plug over contact foot and secure it with the holding screw Attention The given electrical values of the reed contacts shall not be exceeded even for short periods of time For higher switch...

Страница 7: ...e breakage of measuring glass Case 1 with installed unit Open the inlet pipe Let the medium flow through it slowly till the pointer display shows the flow volume of desired switching point Case 2 with...

Страница 8: ...n may lead to increased wear and tear as well as damage to the unit In such cases please consult your supplier With continuous flow if the measuring range is substantially over ranged an increase in p...

Страница 9: ...MW 1 SMW 3 SMO 1 and SMO 3 Electrical connection Plug DIN EN 175301 803 Electrical switching specifications N O contact standard max 250 VAC DC 1 5 A 100 W 100 VA Changeover contact standard max 250 V...

Страница 10: ...2 SMO 2101H SMO 2201H 00 without contact R08 G 1 4 R15 G 1 2 N08 1 4 NPT N15 1 2 NPT 1 4 5 0 2 SMO 2103H SMO 2203H 1 7 5 0 3 SMO 2105H SMO 2205H 1 14 0 4 SMO 2107H SMO 2207H 2 18 0 2 SMO 2109H SMO 220...

Страница 11: ...tact Connection 0 5 3 5 0 2 SMW 2101H SMW 2201H L from left R from right 00 without contact R08 G 1 4 R15 G 1 2 N08 1 4 NPT N15 1 2 NPT 2 9 0 4 SMW 2103H SMW 2203H 2 5 15 0 5 SMW 2105H SMW 2205H 3 5 2...

Страница 12: ...03 30x30 1 4 1 2 132 136 1 SMx 05 30x30 1 4 1 2 132 136 1 SMx 07 30x30 1 4 1 2 132 136 1 SMO 09 30x30 1 4 1 2 132 136 1 SMW 09 30x30 1 2 150 1 SMO 11 30x30 1 4 1 2 156 150 1 7 SMW 11 40x40 3 4 1 156 1...

Страница 13: ...s are available in different sizes When ordering please mention the instrument type 1 1 Float Brass 5 1 N O Contact standard 1 2 Float Stainless Steel 5 2 Changeover Contact standard 2 1 Slotted nozzl...

Страница 14: ...quirements EN 60529 2014 Degrees of protection provided by enclosures IP Code EN 60079 0 2014 Explosive atmospheres Part 0 Equipment General requirements EN 60079 18 2010 Explosive atmospheres Part 18...

Страница 15: ...ol and laboratory use General requirements BS EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP Code BS EN IEC 63000 2018 Technical documentation for the assessment of electrical a...