5 Advanced functions
25
■
Activate the QA analog output
○
Set the parameter in the
QAMENU-SimCur
or
SimVol
menu to the desired signal value.
▫
SimCur for current output
▫
SimVol for voltage output
■
Note: The simulation is automatically deactivated if the supply voltage is interrupted.
Simulating the level
■
Even if there is no liquid in the container yet, it is possible to select a filling level in the menu in
order to test the sensor configuration. When simulating a level value, all outputs on the
NGR
are
set according to the defined configuration. The function should not be selected until a
configuration is
complete.
Configuration
■
Set parameter to the desired filling level as a % in the SimLev menu
■
Note:
○
The level simulation refers to the probe length or container level (probe offset) if an
offset is configured (see Chapter 5.10 "Setting the offset")
○
The simulation is only active when there are no error messages. The simulation is automatically
deactivated if the supply voltage is interrupted.
■
Parameter selection
○
SimOff: Off
○
Fill level 0%
○
Fill level 25%
○
Fill level 50%
○
Fill level 75%
○
Fill level 100%
5.4 Configuring the probe length
■
Log into expert mode (see Chapter 5.1 "Expert mode")
■
Access the
EXPRT-CONFIG-Length
menu using the arrow and Set pushbuttons.
■
Enter the probe length in the
Length
menu. Please note the defined probe length in Chapter 9.8
"Dimensional drawings"
■
Note:
○
HiSpd: max. length = 2,005 mm, response time < 400 ms
○
HiAcc: max. length = 6,005 mm, response time < 2,800 ms
5.5 Teaching in static interference signals
■
Static interference signals in the tank generated by tubes, beams, couplings, or a cleaning ball can
be taught-in. The probe length provides the value for the teach-in depth.
■
Log into expert mode (see Chapter 5.1 "Expert mode")
■
Access the
EXPRT-Config-CalRng
menu using the arrow and Set pushbuttons.
■
Set the value range between 95 and 6,005 mm