4-14
[
4.4.10
EMERGENCY EVACUATION MODE
If the machine should be moved to somewhere emergency even though the machine is in a state of the third level
of warning and under engine restriction due to DEF/AdBlue shortage, abnormal quality, or a failure of the exhaust
gas cleaning device, keep pressing buzzer stop switch (5) and return switch (6) on the switch box for 5 seconds to
enter the emergency evacuation mode.
However, operations other than traveling are restricted, so normal operations become impossible.
• The emergency evacuation mode can be used for only total 30 minutes. Use this mode only in a case of
emergency and if the warnings are displayed, take proper measures immediately.
• When entering the emergency evacuation mode, surely keep pressing buzzer stop switch (5) and return switch
(6) on the switch box for 5 seconds.
If not keep pressing them for 5 seconds securely, the machine will not enter the emergency evacuation mode.
Switch box
(1) Jog dial
(2) Wiper switch
(3) Washer switch
(4) Travel speed select switch
(5) Buzzer stop switch
(6) Return switch
(7) Home switch
4
6
3
2
7
5
1
4.4.11
SCR INSPECTION AND MAINTENANCE
There are parts in SCR that require a periodical inspection and maintenance. (See “SCR SYSTEM" of
"INSPECTION AND MAINTENANCE CHART" in Chapter 4 in the operation manual.)