4-8
[
1
E
F
E
F
2
3.
Press manual regeneration switch (1).
Indication of regenerating (2) is displayed on the
monitor. The engine speed is fixed and the machine
enters the mode for regeneration.
4.
When indication (2) goes off, the manual
regeneration is completed.
When the engine is stopped during the manual
regeneration or when the pilot control shut-off lever
is set to the "UNLOCKED" position, the regeneration
is paused.
In that case, perform the manual regeneration
again.
• It takes about 10 to 20 minutes to complete the manual regeneration.
• Regeneration is performed by increasing the temperature inside the muffler to a certain level. Therefore, the
process completes faster if it is performed immediately after operation, when the temperature inside the muffler
is high.
• It may take more than 20 minutes for combustion when the engine is cool because warming-up is needed before
combustion.
4.3.4
INSPECTION AND MAINTENANCE
• Inspection interval: Every 1,000 hours (or every 1 year)
You need to check the body of the exhaust gas cleaning device for damage, including the sensor cables
attached to the body. If failures are found during inspection, replace the failure parts immediately.
For inspection and replacement, contact KOBELCO or your KOBELCO authorized dealer.
• The inspection and maintenance are needed every 2 years for the body of the exhaust gas cleaning device and
the sensor cables and hoses attached to the body, and the mount. For inspection and maintenance, contact
KOBELCO or your KOBELCO authorized dealer.